Membrane biocompatibility does not affect whole body protein metabolism during dialysis.

Veeneman Jorden M, Kingma Hermi A, Stellaard Frans, de Jong Paul E, Reijngoud Dirk-Jan, Huisman Roel M

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Protein-calorie malnutrition is present in 30-50% of dialysis patients. The lack of biocompatibility of the dialysis membrane, which results in low-grade inflammation, could be responsible for this malnutrition. We investigated whether protein-energy malnutrition could be partly due to incompatibility of the dialyzer during the dialysis session.

METHODS

Five patients were dialyzed during 2 periods of 3 weeks (cross-over) with either a single-use low-flux polysulfone or cellulose triacetate (biocompatible) or a single-use cuprophan (bio-incompatible) membrane. As a measure of whole body protein metabolism, a primed constant infusion of L-[1-(13)C]-valine was used during a 4-hour dialysis session.

RESULTS

Cuprophan was a more powerful activator of the complement system than other membranes. Protein metabolism parameters during both study protocols were not different and resulted in the same protein balance during polysulfone/cellulose triacetate (-15 +/- 3) and cuprophan (-13 +/- 2 micromol/kg/h) dialysis.

CONCLUSION

In stable hemodialysis patients with no apparent complications, protein metabolism during dialysis is not affected by the compatibility of the dialysis membrane.

Для цитирования: Veeneman Jorden M, Kingma Hermi A, Stellaard Frans, de Jong Paul E, Reijngoud Dirk-Jan, Huisman Roel M. Membrane biocompatibility does not affect whole body protein metabolism during dialysis.. Blood purification. 2005. DOI: 10.1159/000084891.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.