DOI 10.1186/s12931-024-02681-w

Медицинская библиотека · Respiratory research · 2024

Diagnostic accuracy of thoracic CT to differentiate transudative from exudative pleural effusion prior to thoracentesis.

Zhang Yan, Zhang Yang, Wang Wei, Feng Xiaoyu, Guo Jiahuan, Chen Bo, Zhang Fuyun, Wang Huanhuan, Fan Mengnan, Zhu Yingwei, Sun Yuxia, Wang Tongsheng, Mao Yimin, Gao Pengfei

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Computed tomography (CT) scan is commonly performed for pleural effusion diagnostis in the clinic. However, there are limited data assessing the accuracy of thoracic CT for the separation of transudative from exudative effusions. The study aimed to determine the diagnostic value of thoracic CT in distinguishing transudates from exudates in patients with pleural effusion.

METHODS

This is a two-center retrospective analysis of patients with pleural effusion, a total of 209 patients were included from The First Affiliated Hospital of Henan University of Science and Technology as the derivation cohort (Luoyang cohort), and 195 patients from the First Affiliated Hospital of Zhengzhou University as the validation cohort (Zhengzhou cohort). Patients who underwent thoracic CT scan followed by diagnostic thoracentesis were enrolled. The optimal cut-points of CT value in pleural fluid (PF) and PF to blood CT value ratio for predicting a transudative vs. exudative pleural effusions were determined in the derivation cohort and further verified in the validation cohort.

RESULTS

In the Derivation (Luoyang) cohort, patients with exudates had significantly higher CT value [13.01 (10.01-16.11) vs. 4.89 (2.31-9.83) HU] and PF to blood CT value ratio [0.37 (0.27-0.53) vs. 0.16 (0.07-0.26)] than those with transudates. With a cut-off value of 10.81 HU, the area under the curve (AUC), sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of CT value were 0.85, 88.89%, 68.90%, 43.96%, and 95.76%, respectively. The optimum cut-value for PF to blood CT value ratio was 0.27 with AUC of 0.86, yielding a sensitivity of 61.11%, specificity of 86.36%, PPV of 78.57%, and NPV of 73.08%. These were further verified in the Validation (Zhengzhou) cohort.

CONCLUSIONS

CT value and PF to blood CT value ratio showed good differential abilities in predicting transudates from exudates, which may help to avoid unnecessary thoracentesis.

Для цитирования: Zhang Yan, Zhang Yang, Wang Wei, Feng Xiaoyu, Guo Jiahuan, Chen Bo, Zhang Fuyun, Wang Huanhuan, Fan Mengnan, Zhu Yingwei, Sun Yuxia, Wang Tongsheng, Mao Yimin, Gao Pengfei. Diagnostic accuracy of thoracic CT to differentiate transudative from exudative pleural effusion prior to thoracentesis.. Respiratory research. 2024. DOI: 10.1186/s12931-024-02681-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.