MedElevator Войти в исследования
← Поиск публикаций

DOI 10.21037/jtd-23-1076

Медицинская библиотека · Journal of thoracic disease · 2023

Pleural fluid soluble Fas ligand and tuberculous pleural effusion: a prospective diagnostic test accuracy study.

Wen Xu-Hui, Wen Jian-Xun, Mu Lan, Cao Xi-Shan, Yan Li, Huang Jin-Hong, Chen Hong, Jiang Ting-Wang, Hu Zhi-De, Niu Yan, Zheng Wen-Qi

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The diagnosis of tuberculous pleural effusion (TPE) is challenging for pulmonologists. Adenosine deaminase (ADA), interferon-gamma (IFN-γ), and interleukin-27 (IL-27) have some limitations for diagnosing TPE. Soluble Fas ligand (sFasL) had a high diagnostic value for TPE. However, it remains unknown: (I) whether sFasL has an additional diagnostic value to the traditional markers (e.g., ADA); (II) whether sFasL provides a net benefit in patients with undiagnosed pleural effusion; (III) factors affecting the diagnostic accuracy of sFasL for TPE. This study aimed to evaluate the additional diagnostic value and benefit of pleural fluid sFasL for TPE.

METHODS

We prospectively enrolled 211 patients with undiagnosed pleural effusion. The concentration of sFasL in pleural fluid was measured by an enzyme-linked immunosorbent assay (ELISA). The diagnostic accuracy and net benefit of sFasL and ADA for TPE were analyzed by a receiver operating characteristic (ROC) curve, decision curve analysis (DCA), net reclassification improvement (NRI), and integrated discriminant improvement (IDI).

RESULTS

The area under the ROC curves (AUCs) of sFasL and ADA were 0.74 (95% CI: 0.65-0.83) and 0.80 (95% CI: 0.71-0.90), respectively. The decision curve of sFasL revealed net benefit. The continuous NRI and IDI of sFasL were 0.36 (0.00-0.72, P=0.05) and 0.02 (-0.01-0.06, P=0.18), respectively.

CONCLUSIONS

Pleural fluid sFasL has moderate diagnostic accuracy for TPE.

Для цитирования: Wen Xu-Hui, Wen Jian-Xun, Mu Lan, Cao Xi-Shan, Yan Li, Huang Jin-Hong, Chen Hong, Jiang Ting-Wang, Hu Zhi-De, Niu Yan, Zheng Wen-Qi. Pleural fluid soluble Fas ligand and tuberculous pleural effusion: a prospective diagnostic test accuracy study.. Journal of thoracic disease. 2023. DOI: 10.21037/jtd-23-1076.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.