MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3760/cma.j.cn112137-20210824-01924

Медицинская библиотека · Zhonghua yi xue za zhi · 2021

[Correlation of preoperative reconstruction of foramen ovale parameters and intraluminal balloon pressure during percutaneous balloon compression for trigeminal neuralgia].

Wang Q, Guo G W, Huang D, Li Z X, Zhou H C

СтатьяПеревод пока не подготовлен

Аннотация

Objective

To explore the relationship between the anatomic parameters of foramen ovale and intraluminal pressure during percutaneous balloon compression (PBC) in the treatment of primary trigeminal neuralgia.

Methods

Twenty patients diagnosed with primary trigeminal neuralgia in the Department of Pain Medicine of the Third Xiangya Hospital, Central South University between November 2020 and April 2021 were enrolled. Three-dimensional (3D) high-resolution CT reconstruction of skull base was performed preoperatively to evaluate the parameters of foramen ovale. The intraluminal balloon pressure was continuously recorded during the PBC procedure. Correlation analysis was conducted between intraluminal pressure and foramen ovale parameters.

Results

Eighteen patients had complete pain relief, 1 had obvious relief, and 1 had partial relief after PBC. The maximum cross-sectional length of the foramen ovale was (7.8±1.7) mm. The peak intraluminal pressure (PM) during PBC was (194±27) kPa. The intraluminal pressure was (164±28) kPa at initial compression (P0), and (135±20) kPa after compression for 120 seconds respectively. Correlation analysis showed that the P0 was positively and significantly correlated with the length of foramen ovale (r=0.56, P<0.05), but not with the width of foramen ovale (r=0.24, P>0.05), the area of foramen ovale (r=0.36, P>0.05) and the degree of balloon filling (r=-0.09, P>0.05). Similarly, P120 was significantly correlated with the length of foramen ovale (r=0.54, P<0.05). No significant correlation was observed between P120 and the width of the foramen ovale (r=0.18, P>0.05), the area of the foramen ovale (r=0.28, P>0.05) or the width of balloon filling (r=-0.13, P>0.05).

Conclusions

The length of foramen ovale correlates with the intraluminal pressure during PBC procedure in trigeminal neuralgia patients. Parameters of foramen ovale obtained via preoperative high-resolution CT reconstruction of skull base may provide reference for predicting targeted intraluminal balloon pressure during PBC.

Для цитирования: Wang Q, Guo G W, Huang D, Li Z X, Zhou H C. [Correlation of preoperative reconstruction of foramen ovale parameters and intraluminal balloon pressure during percutaneous balloon compression for trigeminal neuralgia].. Zhonghua yi xue za zhi. 2021. DOI: 10.3760/cma.j.cn112137-20210824-01924.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.