MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/1476-7120-8-24

Медицинская библиотека · Cardiovascular ultrasound · 2010

Ultrasound-assessed perirenal fat is related to increased ophthalmic artery resistance index in HIV-1 patients.

Grima Pierfrancesco, Guido Marcello, Chiavaroli Roberto, Zizza Antonella

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The introduction of highly active antiretroviral therapy (HAART) has dramatically changed the prognosis of human immunodeficiency virus (HIV) infection, with a significant decline in morbidity and mortality.Changes in body fat distribution are a common finding in individuals with HIV infection being treated with antiretrovirals, and this condition (collectively termed lipodystrophy syndrome) is associated with depletion of subcutaneous fat, increased triglycerides and insulin resistance. Obesity, particularly visceral obesity, is associated with increased risk of cardiovascular disease. Therefore, estimating visceral fat distribution is important in identifying subjects at high risk for cardiovascular disease.The aim of our study was to evaluate whether perirenal fat thickness (PRFT), a parameter of central obesity, is related to ophthalmic artery resistance index (OARI), an index of occlusive carotid artery disease in HIV-1 infected patients.

METHODS

We enrolled 88 consecutive HIV-1-infected patients receiving highly active antiretroviral therapy for more than 12 months, in a prospective cohort study. Echographically measured PRFT and OARI, as well as serum metabolic parameters, were evaluated. PRFT and OARI were measured by 3.75 MHz convex and 7.5 MHz linear probe, respectively.

RESULTS

The means of PRFT and OARI in HIV-1-infected patients with visceral obesity was considerably higher than in patients without it (p < 0.0001 and p < 0.001, respectively). Using the average OARI as the dependent variable, total serum cholesterol level, HDL, triglycerides, glycemia, sex, blood pressure, age and PRFT were independent factors associated with OARI. A PRFT of 6.1 mm was the most discriminatory value for predicting an OARI > 0.74 (sensitivity 78.9%, specificity 82.8%).

CONCLUSIONS

Our data indicate that ultrasound assessment of PRFT may have potential as a marker of increased endothelial damage with specific involvement of the ocular vascular region in HIV-1-infected patients.

Для цитирования: Grima Pierfrancesco, Guido Marcello, Chiavaroli Roberto, Zizza Antonella. Ultrasound-assessed perirenal fat is related to increased ophthalmic artery resistance index in HIV-1 patients.. Cardiovascular ultrasound. 2010. DOI: 10.1186/1476-7120-8-24.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.