MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-2005-870444

Медицинская библиотека · Endoscopy · 2005

Evaluation of a novel colonoscope designed for easier passage through flexures: a randomized study.

Hoff G, Bretthauer M, Huppertz-Hauss G, Sauar J, Paulsen J, Dahler S, Kjellevold Ø

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND AND STUDY AIMS: A new colonoscope (XCF-Q160AW prototype, Olympus, Tokyo, Japan) has been developed, designed with an additional passive bending function to ease intubation through the left colonic flexure. In this study we investigated whether this function could be included in a standard colonoscope without jeopardizing general performance, particularly passage through the sigmoid colon.

PATIENTS AND

METHODS

280 outpatients referred for routine colonoscopy at Telemark Hospital were randomly allocated to colonoscopy with a standard colonoscope (Olympus 140 series) or the XCF-Q160AW prototype. Sedation was given on demand. End points were cecal intubation and the patients' grading of pain in a questionnaire.

RESULTS

Cecal intubation rates were 85% and 87% for standard and prototype endoscopes, respectively (P = 0.57). On-demand sedation was given to nine (7%) and 15 (11%) of the patients, respectively (P = 0.17). Of the patients, 256 (85%) returned their questionnaire, with 87 (63%) in the standard group and 109 (77%) in the prototype group reporting that they had experienced 'no pain/slight pain' (P < 0.001). In a multiple logistic regression analysis, this difference in experienced pain remained statistically significant after adjustment for interendoscopist variation and the use of the endoscope-stiffening function. Two patients in the study, in whom there had previously been several unsuccessful attempts at negotiating the splenic flexure, were successfully examined with the prototype colonoscope.

CONCLUSION

Examination with the Olympus XCF-Q160AW prototype with a passive bending function caused less pain than use of a standard Olympus 140 series colonoscope, without compromising other endoscope functions for colonic intubation.

Для цитирования: Hoff G, Bretthauer M, Huppertz-Hauss G, Sauar J, Paulsen J, Dahler S, Kjellevold Ø. Evaluation of a novel colonoscope designed for easier passage through flexures: a randomized study.. Endoscopy. 2005. DOI: 10.1055/s-2005-870444.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.