OBJECTIVES

This study evaluated a novel offline, AI-driven age-related macular degeneration (AMD) screening algorithm against fundus image-only grading and the standard of care (combined Spectral Domain-Optical Coherence Tomography (SD-OCT) and fundus image grading).

METHODS

Conducted prospectively at a South Asian tertiary eye hospital, this study utilized a validated smartphone-based non-mydriatic fundus camera to capture macula-centred images. The Medios AI's ability to detect referable AMD was compared to a reference standard image grading, using fundus images from the Zeiss Clarus 700 table-top camera and SD-OCT line scan across fovea. Three retina specialists provided blinded AMD diagnoses based on: (1) Zeiss Clarus 700 fundus images alone, and (2) combined SD-OCT and fundus images (standard of care). Referable AMD was defined as intermediate or advanced AMD.

RESULTS

Among 984 eyes from 492 patients (mean age 61.8 ± 9.9 years), 52% had referable AMD. Inter-grader agreement was strong, with Cohen's Kappa scores of 0.81-0.84. The Medios AI's sensitivity and specificity for detecting referable AMD against fundus-only grading (n = 492) were 88.48% (95% CI: 84.04-92.03%) and 87% (95% CI: 81.86-91.11%), respectively. Against combined grading (n = 489), AI sensitivity was 90.62% (95% CI: 86.37-93.90%), and specificity was 85.41% (95% CI: 80.21-89.68%). False negatives were primarily intermediate AMD (71%), while 59% of false positives were early AMD.

CONCLUSION

The novel, automated, offline AMD AI integrated on a smartphone fundus camera demonstrated robust performance in identifying referable forms of AMD, supporting its potential as an affordable and accessible screening solution.

Для цитирования: Negiloni Kalpa, Baskaran Prabu, Rao Divya Parthasarathy, Maitray Aditya, Savoy Florian M, Suresh Shruthi, Mahalingam Maanasi, Vighnesh M J, Rajendran Anand. Advancing AMD screening with an offline, AI-powered smartphone-based fundus camera: A prospective, real-world clinical validation.. Eye (London, England). 2025. DOI: 10.1038/s41433-025-03902-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.