DOI 10.1080/24733938.2025.2471316

Медицинская библиотека · Science & medicine in football · 2025

The effect of knee-flexion angle on peak force and muscle activation during isometric knee-flexor strength testing using the Nordbord device in soccer players.

Taylor Jonathan M, Pallotta Hermes, Smith Phillip, Short Will, Wright Matthew D, Chesterton Paul

СтатьяПеревод пока не подготовлен

Аннотация

Isometric knee-flexor testing is commonplace in soccer, yet data to inform choice of knee-flexion angle are limited. This study aimed to compare peak force production and muscle activation between two isometric knee-flexor tests. To compare peak force, 43 male soccer players (age 21.5 ± 5 years; stature 180.3 ± 6.3 cm; body mass 74.6 ± 8.9 kg) completed 3 × 5-second maximal efforts on the Nordbord device (Vald Performance) with a 0- (ISO-Prone) and 30-degree (ISO-30) knee angle, respectively. To compare peak muscle activation, a further 13 trained male participants (25 ± 6 years; 178.2 ± 5.6 cm; 79.6 ± 13.2 kg) completed 3 × 5-second maximal efforts with wireless surface electromyography electrodes placed on the Gluteus Maximus, Adductor Magnus, Semitendinosus, Biceps Femoris (long and short heads) and Medial Gastrocnemius. Paired samples t-tests were used to detect differences in force output between tests and Pearson's correlations to quantify associations. A Yuen's modified t-test estimated the trimmed mean differences in muscle activation between tests. Higher peak forces were observed in the ISO-30, with mean differences of 56.4N (36.8 to 75.9 [95% CI]) and 52.9N (33.7 to 72.3 [95% CI]) for right (367 vs 314N) and left legs (351 vs 294N), respectively. Moderate correlations were observed in peak force for left (r = 0.55 (0.29 to 0.73 [95%CI])) and right (r = 0.64 (0.42 to 0.79 [95%CI]) legs. No differences in muscle activation were observed. Peak force varies between the ISO-Prone and ISO-30, with moderate associations between tests, indicating that the tests should not be used interchangeably.

Для цитирования: Taylor Jonathan M, Pallotta Hermes, Smith Phillip, Short Will, Wright Matthew D, Chesterton Paul. The effect of knee-flexion angle on peak force and muscle activation during isometric knee-flexor strength testing using the Nordbord device in soccer players.. Science & medicine in football. 2025. DOI: 10.1080/24733938.2025.2471316.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.