Trends and predictors of radiation exposure in percutaneous coronary intervention: the PROTECTION VIII study.
Аннотация
BACKGROUND
Percutaneous coronary intervention (PCI) is indispensable in cardiology; however, exposure to potentially harmful ionising radiation remains a concern.
AIMS: This study was designed to assess the PCI-related radiation dose over the last decade and to identify predictors of increased dose exposure.
METHODS
The PROcedural radiaTion dose Exposure in percutaneous Coronary intervenTION (PROTECTION VIII) study included all PCIs reported to a German quality assurance programme between 2008 and 2018. Dose area product (DAP) and radiation time were analysed. Effective dose (ED) was estimated (ED=DAP*k; conversion coefficient k=0.0022 mSv/cGy*cm2). Multivariate linear regression analysis was used to identify predictors associated with a clinically relevant increase of radiation dose (ED ≥1 mSv).
RESULTS
We enrolled 3,704,986 patients undergoing PCI (median age 70 years, 30% female). Indications were chronic coronary syndrome (37.5%), unstable angina pectoris and non-ST-segment elevation myocardial infarction (non-STEMI; 33.2%) and STEMI (18.5%). Median DAP was 4,203 (interquartile range [IQR] 2,313-7,300) cGy*cm, ED was 9.2 mSv and median radiation time was 9.2 (IQR 5.8-15.0) min. Within the 10-year period, radiation exposure was reduced by 36% (p<0.001) and resulted in a median DAP of 3,070 cGy*cm (ED 6.8 mSv) in 2018. A significant 5.3-fold variability of median DAP was observed between catheterisation laboratories (p<0.001). We identified patient-related (gender, coronary artery bypass graft surgery, heart failure) and procedure-related (coronary occlusion PCI, ostial lesion PCI, left main PCI, multivessel PCI) predictors of increased radiation dose (all p<0.001).
CONCLUSIONS
This radiation dose survey demonstrates a considerable reduction of PCI radiation exposure during the last decade. However, large variability between catheterisation laboratories underlines the need for further radiation dose reduction.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.