MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.toxlet.2020.12.002

Медицинская библиотека · Toxicology letters · 2020

A direct peptide reactivity assay using a high-throughput mass spectrometry screening platform for detection of skin sensitizers.

Wei Zhengxi, Fang Yuhong, Gosztyla Maya L, Li Andrew J, Huang Wenwei, LeClair Christopher A, Simeonov Anton, Tao Dingyin, Xia Menghang

СтатьяПеревод пока не подготовлен

Аннотация

Chemical-peptide conjugation is the molecular initiating event in skin sensitization. The OECD test guideline uses a high-performance liquid chromatography/ultraviolet (HPLC/UV) detection method to quantify chemical-peptide conjugation in a direct peptide reactivity assay (DPRA), which measures the depletion of two synthetic peptides containing lysine or cysteine residues. To improve assay throughput, sensitivity and accuracy, an automated 384-well plate-based RapidFire solid-phase extraction (SPE) system coupled with tandem mass spectrometry (MS/MS) DPRA was developed and validated in the presence of a newly designed internal standard. Compared to the HPLC/UV-based DPRA, the automated SPE-MS/MS-based DPRA improved throughput from 16 min to 10 s per sample, and substrate peptides usage was reduced from 100 mM to 5 μM. When implementing the SPE-MS/MS-based DPRA into a high-throughput platform, we found 10 compounds that depleted lysine peptide and 24 compounds that depleted cysteine peptide (including 7 unreported chemicals from 55 compounds we tested) in a concentration-response manner. The adduct formation between cysteine and cinnamic aldehyde and ethylene glycol dimethacrylate were further analyzed using high-performance liquid chromatography time-of-flight mass spectrometry (HPLC-TOF-MS) to confirm the conjugation. Overall, the automated SPE-MS/MS-based platform is an efficient, economic, and accurate way to detect skin sensitizers.

Для цитирования: Wei Zhengxi, Fang Yuhong, Gosztyla Maya L, Li Andrew J, Huang Wenwei, LeClair Christopher A, Simeonov Anton, Tao Dingyin, Xia Menghang. A direct peptide reactivity assay using a high-throughput mass spectrometry screening platform for detection of skin sensitizers.. Toxicology letters. 2020. DOI: 10.1016/j.toxlet.2020.12.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.