European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2023
Image-based ring size prediction for mitral valve repair.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Akansel Serdar, Kofler Markus, Van Praet Karel M, Sündermann Simon H, Kukucka Marian, Jacobs Stephan, Falk Volkmar, Kempfert Jörg
Аннотация
OBJECTIVES: Annuloplasty rings are routinely used in mitral valve repair (MVr). However, accurate annuloplasty ring size selection is essential to obtain a favourable outcome. Moreover, ring sizing can be challenging in some patients and is highly influenced by surgeons' experience. This study investigated the utility of three-dimensional mitral valve (3D-MV) reconstruction models to predict annuloplasty ring size for MVr.
METHODS: A total of 150 patients undergoing minimally invasive MVr with annuloplasty ring due to Carpentier type II pathology and who were discharged with none/trace residual mitral regurgitation were included. 3D-MV reconstruction models were created with a semi-automated software package (4D MV Analysis) to quantitate mitral valve geometry. To predict the ring size, univariable and multivariable linear regression analyses were performed.
RESULTS: Between 3D-MV reconstruction values and implanted ring sizes, the highest correlation coefficients were provided by commissural width (CW) (0.839; P < 0.001), intertrigonal distance (ITD) (0.796; P < 0.001), annulus area (0.782; P < 0.001), anterior mitral leaflet area (0.767; P < 0.001), anterior-posterior diameter (0.679; P < 0.001) and anterior mitral leaflet length (0.515; P < 0.001). In multivariable regression analysis, only CW and ITD were found to be independent predictors of annuloplasty ring size (R2 = 0.743; P < 0.001). The highest level of agreement was achieved with CW and ITD, and 76.6% of patients received a ring with no >1 ring size difference from the predicted ring sizes.
CONCLUSIONS: 3D-MV reconstruction models can support surgeons in the decision-making process for annuloplasty ring sizing. The present study may be a first step towards accurate annuloplasty ring size prediction using multimodal machine learning decision support.
METHODS: A total of 150 patients undergoing minimally invasive MVr with annuloplasty ring due to Carpentier type II pathology and who were discharged with none/trace residual mitral regurgitation were included. 3D-MV reconstruction models were created with a semi-automated software package (4D MV Analysis) to quantitate mitral valve geometry. To predict the ring size, univariable and multivariable linear regression analyses were performed.
RESULTS: Between 3D-MV reconstruction values and implanted ring sizes, the highest correlation coefficients were provided by commissural width (CW) (0.839; P < 0.001), intertrigonal distance (ITD) (0.796; P < 0.001), annulus area (0.782; P < 0.001), anterior mitral leaflet area (0.767; P < 0.001), anterior-posterior diameter (0.679; P < 0.001) and anterior mitral leaflet length (0.515; P < 0.001). In multivariable regression analysis, only CW and ITD were found to be independent predictors of annuloplasty ring size (R2 = 0.743; P < 0.001). The highest level of agreement was achieved with CW and ITD, and 76.6% of patients received a ring with no >1 ring size difference from the predicted ring sizes.
CONCLUSIONS: 3D-MV reconstruction models can support surgeons in the decision-making process for annuloplasty ring sizing. The present study may be a first step towards accurate annuloplasty ring size prediction using multimodal machine learning decision support.