m+Medelevator.RU
← Поиск публикаций
Biosensors · 2025

FRET Visualization of High Mechanosensation of von Willebrand Factor to Hydrodynamic Force.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ouyang Mingxing, Gao Yao, Zhou Binqian, Guo Jia, Lei Lei, Wang Yingxiao, Deng Linhong

Аннотация

von Willebrand factor (vWF) is a large glycoprotein in the circulation system, which senses hydrodynamic force at vascular injuries and then recruits platelets in assembling clots. How vWF mechanosenses shear flow for molecular unfolding is an important topic. Here, a Förster resonance energy transfer (FRET) biosensor was developed to monitor vWF conformation change to hydrodynamic force. The vWF-based biosensor is anchored on the cell surface, in which the A2 domain is flanked with a FRET pair. With 293T cells seeded into microfluidic channels, 2.8 dyn/cm2 of shear force (i.e., 28 μN/cm2, or 264.1/s in shear rate) induced a remarkable FRET change (~60%) in 30 min. A gradient micro-shear below 2.8 dyn/cm2 demonstrated FRET responses positively related to flow magnitudes, with 0.14 dyn/cm2 (1.4 μN/cm2) inducing an obvious change (~16%). The FRET increases indicate closer positioning of A2's two terminals in vWF or the addition of a more parallel orientation of the FRET pair, supported with the high FRET of the A2-only-based biosensor, which probably resulted from flow-induced A2 dissociation from vWF intramolecular binding such as that in A1/A3 domains. Interestingly, gradient flow increases from 2.8 to 28 dyn/cm2 led to decreasing FRET changes, suggesting the second-level unfolding in the A2 domain. The LOCK-vWF biosensor with bridged A2 two terminals or an A2-only biosensor could not sense the shear, indicating a structure-flexible A2 and large vWF molecules that are important in the mechanosensation. In conclusion, the developed vWF-based biosensor demonstrated the high mechanosensation of vWF with two-level unfolding to shear force: the dissociation of the A2 domain from vWF intramolecular binding under a micro-shear, and then the unfolding of A2 in vWF under a higher shear; the FRET response to shear force at a very low scale may support the observed clot formation at microvascular wounds. This study provides new insights into the vWF's mechanosensitive feature for its physiological functions and implicated disorders.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты