MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00408-022-00590-7

Медицинская библиотека · Lung · 2022

Shape-Sensing Robotic-Assisted Bronchoscopy with Concurrent use of Radial Endobronchial Ultrasound and Cone Beam Computed Tomography in the Evaluation of Pulmonary Lesions.

Styrvoky Kim, Schwalk Audra, Pham David, Chiu Hsienchang T, Rudkovskaia Anastasiia, Madsen Kristine, Carrio Stephen, Kurian Elizabeth M, De Las Casas Luis, Abu-Hijleh Muhanned

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Lung nodules are a common radiographic finding. Non-surgical biopsy is recommended in patients with moderate or high pretest probability for malignancy. Shape-sensing robotic-assisted bronchoscopy (ssRAB) combined with radial endobronchial ultrasound (r-EBUS) and cone beam computed tomography (CBCT) is a new approach to sample pulmonary lesions. Limited data are available regarding the diagnostic accuracy of combined ssRAB with r-EBUS and CBCT.

METHODS

We conducted a retrospective analysis of the first 200 biopsy procedures of 209 lung lesions using ssRAB, r-EBUS, and CBCT at UT Southwestern Medical Center in Dallas, Texas. Outcomes were based on pathology interpretations of samples taken during ssRAB, clinical and radiographic follow-up, and/or additional sampling.

RESULTS

The mean largest lesion dimension was 22.6 ± 13.3 mm with a median of 19 mm (range 7 to 73 mm). The prevalence of malignancy in our data was 64.1%. The diagnostic accuracy of ssRAB combined with advanced imaging was 91.4% (CI 86.7-94.8%). Sensitivity was 87.3% (CI 80.5-92.4%) with a specificity of 98.7% (CI 92.8-100%). The negative and positive predictive values were 81.3% and 99.2%. The rate of non-diagnostic sampling was 11% (23/209 samples). The only complication was pneumothorax in 1% (2/200 procedures), with 0.5% requiring a chest tube.

CONCLUSION

Our results of the combined use of ssRAB with r-EBUS and CBCT to sample pulmonary lesions suggest a high diagnostic accuracy for malignant lesions with reasonably high sensitivity and negative predictive values. The procedure is safe with a low rate of complications.

Для цитирования: Styrvoky Kim, Schwalk Audra, Pham David, Chiu Hsienchang T, Rudkovskaia Anastasiia, Madsen Kristine, Carrio Stephen, Kurian Elizabeth M, De Las Casas Luis, Abu-Hijleh Muhanned. Shape-Sensing Robotic-Assisted Bronchoscopy with Concurrent use of Radial Endobronchial Ultrasound and Cone Beam Computed Tomography in the Evaluation of Pulmonary Lesions.. Lung. 2022. DOI: 10.1007/s00408-022-00590-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.