m+Medelevator.RU
← Поиск публикаций
The Journal of thoracic and cardiovascular surgery · 2013

Repair of posterior mitral valve prolapse with a novel leaflet plication clip in an animal model.

Оценочное исследованиеСтатьяПоддержка NIH: внешняя программаVideo-Audio MediaНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Feins Eric N, Yamauchi Haruo, Marx Gerald R, Freudenthal Franz P, Liu Hua, Del Nido Pedro J, Vasilyev Nikolay V

Аннотация

OBJECTIVE: Recently, there has been increased interest in minimally invasive mitral valve prolapse repair techniques; however, these techniques have limitations. A new technique was developed for treating mitral valve prolapse that uses a novel leaflet plication clip to selectively plicate the prolapsed leaflet segment. The clip's efficacy was tested in an animal model.

METHODS: Yorkshire pigs (n = 7) were placed on cardiopulmonary bypass (CPB), and mitral valve prolapse was created by cutting chordae supporting the P2 segment of the posterior leaflet. Animals were weaned off CPB and mitral regurgitation (MR) was assessed echocardiographically. CPB was reinitiated and the plication clip was applied under direct vision to the P2 segment to eliminate the prolapse. The animals survived for 2 hours. Epicardial echocardiography was obtained before and after prolapse creation and 2 hours after clip placement to quantify MR grade and vena contracta area. Posterior leaflet mobility and coaptation height were analyzed before and after clip placement.

RESULTS: There were no cases of clip embolization. Median MR grade increased from trivial (0-1.5) to moderate-severe after MR creation (2.5-4+) (P < .05), and decreased to mild after clip placement (0-3+) (P < .05). Vena contracta area tended to increase after cutting the chordae and decrease after clip placement: 0.08 ± 0.10 cm(2) versus 0.21 ± 0.15 cm(2) versus 0.16 ± 0.16 cm(2) (P = .21). The plication clip did not impair leaflet mobility. Coaptation height was restored to baseline: 0.51 ± 0.07 cm versus 0.44 ± 0.18 cm (P = 1.0).

CONCLUSIONS: The leaflet plication clip can treat mitral valve prolapse in an animal model, restoring coaptation height without affecting leaflet mobility. This approach is a simple technique that may improve the effectiveness of beating-heart and minimally invasive valve surgery.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты