MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/deo2.150

Медицинская библиотека · DEN open · 2022

Hemostasis using a covered self-expandable metal stent for pseudoaneurysm bleeding from the perihilar bile duct.

Ishii Yu, Nakayama Akihiro, Kikuchi Kazuo, Nakatani Kei, Konda Kenichi, Mori Daichi, Nishihara Shigetoshi, Oikawa Shu, Nomoto Tomohiro, Usami Tomono, Noguchi Toshihiro, Mitsui Yuta, Yoshida Hitoshi

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

Although there are many reports of hemostasis with covered self-expandable metal stent (CSEMS) for bleeding from the papilla of Vater and the intrapapillary and distal bile duct, there are rare reports of its use for hemostasis in the perihilar bile duct. We report the case of a patient undergoing supportive care for perihilar cholangiocarcinoma with acute cholecystitis after side-by-side placement of uncovered SEMS for perihilar bile duct obstruction. Percutaneous transhepatic gallbladder aspiration was performed upon admission, and hematemesis occurred the next day. Since computed tomography scanning showed a pseudoaneurysm in the right uncovered SEMS, hemostasis by interventional radiology (IVR) was performed thrice for massive bleeding; however, hemostasis could not be achieved. When endoscopic retrograde cholangiopancreatography was performed for scrutiny and treatment of melena and increased hepatobiliary enzyme, the endoscopic visual field could not be secured by bleeding, and changes in hemodynamics were observed; thus, IVR was required, but it was difficult to perform. Since bleeding from the right bile duct was expected, hemostasis was performed using CSEMS. This is the first report of hemostasis performed by placing a covered SEMS for bleeding from a pseudoaneurysm of the intrahepatic bile duct.

Для цитирования: Ishii Yu, Nakayama Akihiro, Kikuchi Kazuo, Nakatani Kei, Konda Kenichi, Mori Daichi, Nishihara Shigetoshi, Oikawa Shu, Nomoto Tomohiro, Usami Tomono, Noguchi Toshihiro, Mitsui Yuta, Yoshida Hitoshi. Hemostasis using a covered self-expandable metal stent for pseudoaneurysm bleeding from the perihilar bile duct.. DEN open. 2022. DOI: 10.1002/deo2.150.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.