MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11604-010-0482-5

Медицинская библиотека · Japanese journal of radiology · 2010

Segmental acquisition method for stationary objects in (18)F-fluorodeoxyglucose positron emission tomography tests.

Tsuda Keisuke, Aikawa Naoyuki, Suzuki Takayuki, Moriya Etsuo, Yamaguchi Masayuki, Kitamura Hideaki, Hanai Kouzou, Umeda Izumi O, Fukushi Masahiro, Moriyama Noriyuki, Fujii Hirofumi

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: We investigated whether images of stationary objects obtained by segmental acquisition with positron emission tomography using 2-deoxy-2-[(18)F]-fluoro-D: -glucose (FDG-PET) are of a quality equivalent to those obtained by conventional continuous acquisition.

MATERIALS AND

METHODS

Phantoms filled with FDG and mid-abdominal regions of 18 patients who underwent FDG-PET tests were imaged by both continuous and segmental acquisition methods. The total acquisition time was set to 3 min; in the segmental acquisition mode, imaging for 15 s was repeated 12 times. Segmental images (SIs) obtained by superimposition of the reconstructed images were compared quantitatively and visually with continuous images (CIs).

RESULTS

In all the phantom and clinical studies, SIs were never worse than CIs. The variances of the background counts of SIs were 9.8% and 13.0% less those of CIs in phantom and clinical studies, respectively. Visual assessments showed that SIs provided better detection of hot areas and superior image quality when compared to CIs.

CONCLUSION

For stationary objects, the quality of images obtained by the segmental method is equivalent to that of images obtained conventionally by continuous acquisition. Moreover, under some conditions SIs provide better results than CIs.

Для цитирования: Tsuda Keisuke, Aikawa Naoyuki, Suzuki Takayuki, Moriya Etsuo, Yamaguchi Masayuki, Kitamura Hideaki, Hanai Kouzou, Umeda Izumi O, Fukushi Masahiro, Moriyama Noriyuki, Fujii Hirofumi. Segmental acquisition method for stationary objects in (18)F-fluorodeoxyglucose positron emission tomography tests.. Japanese journal of radiology. 2010. DOI: 10.1007/s11604-010-0482-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.