Comparison of visual interpretation of [I-123] FP-CIT SPECT scans versus reference-based quantitative analysis utilizing a Japanese normal database.

Yamakuni Ryo, Ishii Shiro, Fukushima Kenji, Kakamu Takeyasu, Yusa Masanori, Kikori Katsuyuki, Yamao Tensho, Takahashi Noriyuki, Sekino Hirofumi, Itagaki Shuntaro, Miura Itaru, Ito Hiroshi

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

Dopamine transporter single-photon emission computed tomography (DAT-SPECT) plays an important role in diagnosing parkinsonism. Recently, a reference-based quantitative analysis utilizing a Japanese normal database for DAT-SPECT was developed. This study aimed to investigate the frequency and trends of cases wherein the analysis- and physician-based diagnoses diverged.

METHODS

Two physicians performed an interpretation task twice on 195 DAT-SPECT scans. After assessing intra- and intertester agreements, disagreements were resolved by consensus. For the reference-based quantitative analysis, the calibrated specific binding ratio (cSBR), calibrated asymmetry index (cAI), and Z-scores were measured. Images were grouped according to physician consensus and the negative-positive difference from thresholds (Z-score of less than -2.0 and/or cAI of more than 12.22) as follows: group 1 (physician, normal; quantitative analysis, normal; n  = 70), group 2 (abnormal; normal; n  = 4), group 3 (normal; abnormal; n  = 31), and group 4 (abnormal; abnormal; n  = 90).

RESULTS

Median cSBRs and Z-scores decreased in order from group 1 to group 4. Median cAI values increased in the order of groups 1, 3, 2, and 4. Significant differences were observed between groups 1 and 2 for cSBRs and cAIs; groups 2 and 3 for Z-scores; groups 2 and 4 for cSBRs and Z-scores; and groups 1 and 3, 1 and 4, and 3 and 4 for all parameters (Kruskal-Wallis and Steel-Dwass tests).

CONCLUSION

In approximately 18% of cases, the visual interpretation of physicians diverged from the reference-based quantitative analysis based on a Japanese normal database. It is crucial to appropriately utilize DAT-SPECT reference-based quantitative analysis as a diagnostic aid.

Для цитирования: Yamakuni Ryo, Ishii Shiro, Fukushima Kenji, Kakamu Takeyasu, Yusa Masanori, Kikori Katsuyuki, Yamao Tensho, Takahashi Noriyuki, Sekino Hirofumi, Itagaki Shuntaro, Miura Itaru, Ito Hiroshi. Comparison of visual interpretation of [I-123] FP-CIT SPECT scans versus reference-based quantitative analysis utilizing a Japanese normal database.. Nuclear medicine communications. 2025. DOI: 10.1097/mnm.0000000000001968.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.