Ultrasound features of the subungual glomus tumor and squamous cell carcinomas.
Аннотация
BACKGROUND
Nail tumors often pose a significant challenge for the clinician, as they are burdened by a high delay in diagnosis and paucity of clinical signs in the early stage. In most cases, the onset of pain or nail plate dystrophy leads to imaging investigations such as plain radiography, magnetic resonance imaging, and ultrasonography (US) when surgery is pending.
MATERIAL AND
METHODS
A 2-year monocentric study evaluated the histologically confirmed cases of subungual glomus tumor (GT) and squamous cell carcinoma (SCC) with a pre-surgical US assessment, and reviewed their sonography features. A total of 7 digital GTs and 6 SCCs of the nail were collected.
RESULTS
GT and SCC are easily distinguishable on US. Compared to SCC, GT was positively associated with an ovoid shape, well-defined borders, bone cup-scalloping without cortical erosion, and a rich intralesional vascular pattern (P < 0.05). Vice versa, SCC was significantly correlated with irregular shape, ill-circumscribed margins, an infiltrative growth pattern with peripheral hypoechoic foci, posterior acoustic shadow, cortical erosion, and a highly vascular multipolar peripheral pattern (P < 0.05).
CONCLUSION
The rapid assessment of GT and SCC sonographic features may contribute to reduce diagnostic delay, expedite management, and decrease the risk of surgical relapse.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.