MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0218492314548230

Медицинская библиотека · Asian cardiovascular & thoracic annals · 2014

Endovascular repair for retrograde type A aortic dissection with malperfusion.

Takahashi Shinya, Katayama Keijiro, Takasaki Taiichi, Sueda Taijiro

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

An 81-year-old man became semiconscious and suffered back pain followed by chest pain. Computed tomography showed retrograde acute type A aortic dissection with entries in the proximal and middle descending aorta, and an occluded true lumen of the right carotid artery. Emergency endovascular repair was performed. Immediately after deploying a stent-graft, aortography showed recanalization of the right carotid artery and no blood flow in the false lumen of the ascending aorta and aortic arch. The postoperative course was uneventful. Computed tomography at 6 months after the procedure showed obliteration of the false lumen and a patent right carotid artery.

Для цитирования: Takahashi Shinya, Katayama Keijiro, Takasaki Taiichi, Sueda Taijiro. Endovascular repair for retrograde type A aortic dissection with malperfusion.. Asian cardiovascular & thoracic annals. 2014. DOI: 10.1177/0218492314548230.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.