Proximal thoracic endograft displacement rescued by balloon-assisted pull-back, external shunting, and in situ fenestration of the left carotid artery.

Tsilimparis Nikolaos, Debus E Sebastian, Wipper Sabine, Carpenter Sebastian, Lohrenz Christina, Kölbel Tilo

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

Proximal displacement of thoracic aortic endografts is a catastrophic adverse event, which rarely occurs but is associated with extremely high morbidity and mortality. We describe herein the case of a patient with accidental proximal displacement of a thoracic endograft with occlusion of all supra-aortic branches, successfully rescued by the combination of three advanced endovascular techniques: (1) aggressive pull-back maneuver with a compliant balloon; (2) establishment of an arterio-arterial temporary shunt to the occluded carotid artery over sheaths; and (3) in-situ fenestration of the occluded carotid artery.

Для цитирования: Tsilimparis Nikolaos, Debus E Sebastian, Wipper Sabine, Carpenter Sebastian, Lohrenz Christina, Kölbel Tilo. Proximal thoracic endograft displacement rescued by balloon-assisted pull-back, external shunting, and in situ fenestration of the left carotid artery.. Journal of vascular surgery. 2014. DOI: 10.1016/j.jvs.2014.05.043.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.