MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/1081597x-20210115-01

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2021

Visual and Tomographic Outcomes of a 300° Arc-length ICRS Implantation in Moderate to Advanced Central Keratoconus.

Alfonso José F, Torquetti Leonardo, Fernández-Vega-Cueto Luis, Allan Bruce, Poo-López Aranzazu, Alfonso-Bartolozzi Belén, de la Cruz José, Monteiro Tiago, Madrid-Costa David

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To assess the outcomes of implanting a new 300° arc-length intrastromal corneal ring segment (ICRS) in moderate to advanced central hyperprolate keratoconus.

METHODS

Forty-two eyes with moderate to advanced central hyperprolate keratoconus were evaluated before and after implanting an inferior 300° ICRS (AJL Ophthalmic). The clinical measurements taken included manifest refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuity (logMAR scale), and corneal tomographic analysis (Sirius; Costruzioni Strumenti Oftalmici). Changes in the anterior and posterior corneal surfaces and the root mean square (RMS) for coma-like aberrations for a pupil size of 4.5 mm were evaluated. All examinations were performed before surgery and 6 months after surgery.

RESULTS

The mean UDVA improved from 1.12 ± 0.48 logMAR preoperatively to 0.73 ± 0.37 logMAR postoperatively (P < .0001). The mean CDVA changed from 0.33 ± 0.20 to 0.20 ± 0.11 logMAR (P < .0001). Postoperatively, the CDVA improved by two or more lines in 45.2% of the eyes and increased by one line in 19.04%, and none of the patients lost lines of CDVA. All of the anterior and posterior corneal tomographic parameters analyzed were significantly improved after surgery, except posterior flat keratometry, which remained unchanged. In 80.95% of the eyes, the postoperative mean keratometry was 50.00 diopters or less. The 6-month RMS for coma-like aberrations also declined significantly from 1.57 ± 0.68 to 1.06 ± 0.42 µm after surgery (P < .0001).

CONCLUSIONS

These results suggest that implanting a 300° arc-length ICRS is a safe and effective procedure for treating patients with moderate to advanced central hyperprolate keratoconus and clear cornea. [J Refract Surg. 2021;37(4):249-255.].

Для цитирования: Alfonso José F, Torquetti Leonardo, Fernández-Vega-Cueto Luis, Allan Bruce, Poo-López Aranzazu, Alfonso-Bartolozzi Belén, de la Cruz José, Monteiro Tiago, Madrid-Costa David. Visual and Tomographic Outcomes of a 300° Arc-length ICRS Implantation in Moderate to Advanced Central Keratoconus.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2021. DOI: 10.3928/1081597x-20210115-01.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.