MedElevator Войти в исследования
← Поиск публикаций

DOI 10.22336/rjo.2021.16

Медицинская библиотека · Romanian journal of ophthalmology · 2021

Surprising astigmatism hypercorrection after corneal ring segments implantation in keratoconus treatment after 8 years of follow up.

Guilherme Malta Pio, Frederico Malta Pio, Alessandra Mariano Caldeira Coelho, Carolina Serpa Braga, Anna Flávia Ribeiro Pereira, Caroline Alves Cotrim, Frederico Bicalho Dias Silva

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

Objective

To report a case of hypercorrection of astigmatism (Cyl) after implantation of 2 segments of short arch ring for keratoconus treatment and to describe its replacement by long arch segment.

Methods

This is a case report of a patient with keratoconus and no adaptation to glasses or contact lenses, who was implanted 2 ring segments: upper nasal (155º/ 200μm) and inferior temporal (155º/ 250μm).

Results

First postoperative month: CVA = 20/ 50 (-10.50-2.50x135°) and SimK K1 = 48.4x143° and K2 = 51.2x53° (Cyl 2,8D). In the 3rd year: CVA 20/ 30 (-6.00-2.50x135º), with inversion of the axes: K1 = 49,5x60º and K2 = 52,0x150º (Cyl 2,6D). The hypercorrection increased up to the 8th year: CVA = 20/40 (-4,50-6,00x75º) and SimK 47,8x51º/ 60,4x141º (Cyl 12,6D). The 2 segments were replaced for a single segment (320º/ 300μm) and after 1 month: CVA = 20/ 25 (-5,75 spherical) with SimK 46,8x38º/ 48,9x128º (Cyl 2,1D).

Conclusion

The ring aims to flatten the most curved meridian, but surpassing the previous value induces astigmatism in the opposite meridian. The hypercorrection of the 2 short segments must occur due to its movement of the extremities, which does not occur with the single long arc segment (≥ 300º). Abbreviations: CVA = Corrected visual acuity, SimK = Simulated keratometry, LE = Left eye, RE = Right eye.

Для цитирования: Guilherme Malta Pio, Frederico Malta Pio, Alessandra Mariano Caldeira Coelho, Carolina Serpa Braga, Anna Flávia Ribeiro Pereira, Caroline Alves Cotrim, Frederico Bicalho Dias Silva. Surprising astigmatism hypercorrection after corneal ring segments implantation in keratoconus treatment after 8 years of follow up.. Romanian journal of ophthalmology. 2021. DOI: 10.22336/rjo.2021.16.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.