MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s40662-021-00234-6

Медицинская библиотека · Eye and vision (London, England) · 2021

The number of intracorneal ring segments in asymmetric and central cones.

Utine Canan Asli, Özizmirliler Denizcan, Kayabaşı Mustafa, Günenç Üzeyir

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

To compare the results of single versus double intracorneal ring segment (ICRS) (KeraRing) implantation in keratoconus with respect to different cone locations.

METHODS

Twenty-two eyes of 18 patients with totally asymmetric cones (20-80% or 0-100% distribution along steep axis) were implanted with single ICRS (Group 1), 38 eyes of 32 patients with central or partially asymmetric cones (50-50% or 40-60% distribution along steep axis) were implanted with double ICRS (Group 2), at a depth of 80% of the site of implantation, in channels created with femtosecond laser device. All patients had uncorrected and corrected distance visual acuities (UDVA and CDVA, respectively) of ≤ 0.3 Snellen lines.

RESULTS

In both groups, patients had median UDVA and CDVA gain of 3 Snellen lines (P > 0.05). Postoperative improvement in indices of vertical asymmetry and height decentration in Group 1; simulated keratometry, corneal astigmatism and anterior corneal asphericity values in Group 2 were greater (P < 0.05). A total of 10 eyes (45.5%) in Group 1 were recommended double ring implantation by the manufacturer's nomogram, but underwent single ICRS implantation and achieved visual, refractive, tomographic outcomes comparable to that in Group 2, although corneal cylindrical correction was less and final topographic astigmatism was greater.

CONCLUSION

Double ICRS implantation seems to be superior in terms of keratometry, corneal astigmatism and anterior corneal asphericity improvement. Single ICRS implantation in totally asymmetric cones seems to provide satisfactory visual, refractive and tomographic results, similar to double ICRS implantation in central and partially asymmetric cones, by inducing central shift of the cone.

Для цитирования: Utine Canan Asli, Özizmirliler Denizcan, Kayabaşı Mustafa, Günenç Üzeyir. The number of intracorneal ring segments in asymmetric and central cones.. Eye and vision (London, England). 2021. DOI: 10.1186/s40662-021-00234-6.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.