Outcomes and complications of implantable collamer lens for mild to advance keratoconus.

Fairaq Rafah, Almutlak Mohammed, Almazyad Enmar, Badawi Abdulrahman H, Ahad Muhammad Ali

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the outcome and safety of implantable collamer lens (ICL; (Visian, STAAR Surgical, Monrovia, CA, USA) in mild to advance keratoconus patients with myopia and myopic astigmatism.

METHODS

This retrospective study evaluated all patients who underwent ICL implantation for the management of keratoconus at a tertiary care eye hospital from January 2012 to January 2018. The mean duration of follow-up was 15.3 months (range, 3.13 to 38.97 months). Data were collected on preoperative and postoperative uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA), refraction was compared, and adverse effects were evaluated.

RESULTS

Thirty-two eyes (32 patients) were evaluated. The median CDVA was 20/30 preoperatively and 20/20 at last follow-up. The median UDVA was 20/25 at last follow-up. Thirteen patients (40.6%) had 20/20 UDVA in comparison to none at baseline. The median spherical equivalent in diopters (D) was -7.875 D (-4.125 to -10.0 D) preoperatively and decreased to -0.3125 D at last follow-up. The median manifest refractive cylinder was 3.00 D (2.25 to 5.25 D) preoperatively and decreased to 1.125 D postoperatively. Cylinder axis rotation of 10° or greater occurred in 3 eyes (9.375%) and required repositioning of the ICL. One patient (3%) developed nonvisually significant anterior subcapsular cataract. One ICL (3.125%) had to be explanted due to residual refractive error and unsatisfactory vision.

CONCLUSION

ICLs are a suitable refractive option for the correction of refractive error associated with stable, nonprogressive keratoconus even in advance cases. However, the risk of ICL rotation and subsequent repositioning remain. Careful patient selection is necessary for achieving good outcomes and mitigating intraoperative and postoperative complications.

Для цитирования: Fairaq Rafah, Almutlak Mohammed, Almazyad Enmar, Badawi Abdulrahman H, Ahad Muhammad Ali. Outcomes and complications of implantable collamer lens for mild to advance keratoconus.. International ophthalmology. 2021. DOI: 10.1007/s10792-021-01820-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.