MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.recot.2019.03.002

Медицинская библиотека · Revista espanola de cirugia ortopedica y traumatologia (English ed.) · 2019

Results measured by means of a motion capture system in proximal humerus fractures treated by osteosynthesis with locking plate.

Gómez-Blasco A M, Hernández-Fernández A, Roche-Albero A, Martín-Hernández C

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the results after locking plate internal fixation of proximal humerus fractures by means of a motion capture system, and functional scales.

MATERIAL AND METHOD: Retrospective study of a cohort of 47 elderly patients undergoing surgery from January 2010 to December 2014. After a minimum follow-up of two years, two functional scales (Constant-Murley and Quick DASH), and a quality of life scale (EQ-5D) were used for clinical evaluation. For objective evaluation of the range of motion a kinematic marker-free analysis with cameras was performed.

RESULTS

The average age was 74.85 years. Average functional scores were: Constant-Murley 70.06 points, Quick DASH 35.74 points and EQ-5D 6.79 points. The average range of motion was: flexion, 111.49°; extension: 24.13°; abduction: 109.40°; adduction: 15.13°; external rotation: 38.96°, and internal rotation: 49.28°. Correlation was found between the two functional scales, between them and the EQ-5D, and between range of motion and functional scales (except for external rotation) as well as between range of motion and EQ-5D (except for flexion and external rotation).

CONCLUSION

Locking plate osteosynthesis in proximal humerus fragility fractures achieved good functional and quality of life scores. Motion capture systems can be a useful tool for the functional assessment of shoulder pathology allowing an objective evaluation of range of motion.

Для цитирования: Gómez-Blasco A M, Hernández-Fernández A, Roche-Albero A, Martín-Hernández C. Results measured by means of a motion capture system in proximal humerus fractures treated by osteosynthesis with locking plate.. Revista espanola de cirugia ortopedica y traumatologia (English ed.). 2019. DOI: 10.1016/j.recot.2019.03.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.