MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/1081597x-20201123-03

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2021

Two-Year Follow-up of Intracorneal Ring Segments Implantation in Adolescent Patients With Keratoconus.

Peris-Martínez Cristina, Hernández-Díaz Mikhail, Roig-Revert Maria José, Alfonso-Muñoz Enrique, Montolío-Marzo Santiago, Monsálvez-Romín Daniel

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the visual, refractive, topographic, and aberrometric outcomes after intracorneal ring segments (ICRS) implantation in adolescent patients with keratoconus.

METHODS

A retrospective longitudinal study was undertaken with a total of 61 eyes from 47 patients with keratoconus, aged between 13 and 18 years, implanted with a Ferrara-type ICRS. Topography (flattest keratometry, steepest keratometry, and asphericity), uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refractive error (sphere and cylinder), and aberrometric measurements (spherical aberration and vertical coma) were evaluated before surgery and at 1 month, 6 months, 1 year, and 2 years after surgery.

RESULTS

UDVA exhibited a statistically significant increase at all times from 1 month to 2 years postoperatively (P < .001), whereas CDVA showed a statistically significant improvement at 1 month, 6 months, and 2 years (P < .002), but dropped in significance at 1 year postoperatively (P = .097). The refractive error analysis showed no variation in statistical significance in the sphere (P = .712) after 2 years. The cylinder presented a statistically significant decrease in diopters at all times from preoperatively to 2 years postoperatively (P < .007). Steepest keratometry manifested a statistically significant decrease in steepness at all times after surgery (P < .001), whereas flattest keratometry lost significance at 1 year (P = .298) and 2 years (P = .053) postoperatively. There was no statistically significant change in the spherical aberration at any of the measured times. The vertical coma was only significantly different at 2 years postoperatively (P = .001).

CONCLUSIONS

ICRS implantation is a safe and effective treatment for improving visual and corneal morphological parameters as shown at 2 years of follow-up in adolescent patients with keratoconus. It is a good option to flatten and regularize the cornea and to temporarily improve the quality of life of young patients and delay the need for keratoplasty. [J Refract Surg. 2021;37(2):91-97.].

Для цитирования: Peris-Martínez Cristina, Hernández-Díaz Mikhail, Roig-Revert Maria José, Alfonso-Muñoz Enrique, Montolío-Marzo Santiago, Monsálvez-Romín Daniel. Two-Year Follow-up of Intracorneal Ring Segments Implantation in Adolescent Patients With Keratoconus.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2021. DOI: 10.3928/1081597x-20201123-03.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.