MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/opx.0000000000001645

Медицинская библиотека · Optometry and vision science : official publication of the American Academy of Optometry · 2021

Comparative Analysis of Tear Proteins in Keratoconic Scleral Lens Wearers with Variation in Limbal Clearance.

Yeung Debby, Murphy Paul J, Sorbara Luigina

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

SIGNIFICANCE: Cytokine and protease analysis revealed relative changes in the post-lens tear film of scleral lenses with low and high limbal clearances. Results from this study indicate that midperipheral lens fit is an important fitting feature that can impact the inflammatory response of a keratoconic eye.

PURPOSE: The purpose of this study was to investigate changes in levels of inflammatory mediators in the post-lens tear film of keratoconic scleral lens wearers with varying limbal clearance designs.

METHODS

Twenty-two keratoconic eyes were fitted with two sets of scleral lenses that were consistent in lens diameter and central sagittal depth but varied in limbal clearance by approximately 50 μm. Lenses were worn in a randomly assigned order for a 2-week period each. At each follow-up visit, immediately after lens removal, tear samples were collected with a microcapillary tube (10 μL, 0.5 mm in diameter) from the bowl of the inverted scleral lens. Tear cytokine and protease analysis was performed using a multiplex electrochemiluminescent array (Meso Scale Discovery, Rockville, MD) instrument. Levels of interleukins 1, 6, and 8; tumor necrosis factor α; and matrix metalloproteinases 1 and 9 were compared and analyzed.

RESULTS

Levels of interleukin 1β, tumor necrosis factor α, and matrix metalloproteinase 1 increased with high limbal clearance (P = .01, .006, and .02, respectively). No change in interleukins 6 and 8 levels was found (P > .05). A decrease in matrix metalloproteinase 9 was noted in post-lens tear film of scleral lenses with high limbal clearance (P = .10).

DISCUSSION: Relative changes in the cytokine and protease levels were found when comparing low and high limbal clearance, indicating that the midperipheral lens fit is an important feature that can impact the inflammatory response of the keratoconic eye.

Для цитирования: Yeung Debby, Murphy Paul J, Sorbara Luigina. Comparative Analysis of Tear Proteins in Keratoconic Scleral Lens Wearers with Variation in Limbal Clearance.. Optometry and vision science : official publication of the American Academy of Optometry. 2021. DOI: 10.1097/opx.0000000000001645.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.