MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/1081597x-20201005-01

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2020

Customized Stromal Lenticule Implantation for Keratoconus.

Doroodgar Farideh, Jabbarvand Mahmoud, Niazi Sana, Karimian Farid, Niazi Feizollah, Sanginabadi Azad, Ghoreishi Mohammad, Alinia Cyrus, Hashemi Hassan, Alió Jorge L

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate the potential benefit of keratoconus surgery using customized corneal stromal donor lenticules obtained from myopic small incision lenticule extraction (SMILE) surgery by femtosecond laser.

METHODS

In this prospective, consecutive, non-comparative series of cases, 22 lenticules were obtained from 22 myopic patients who had SMILE with a lenticule central thickness of greater than 110 µm. The lenticules were implanted in 22 eyes with advanced keratoconus. The lenticules were customized for the purpose of the implantation with either a simple necklace or necklace-with-ring shape (compound form) depending on the corneal thickness and corneal topography configuration of the implanted keratoconic eyes. The lenticules were implanted into a 9.5-mm corneal lamellar pocket created by the femtosecond laser. Changes in densitometry, thickness, confocal microscopy, corrected distance visual acuity (CDVA), and endothelial cell density were investigated.

RESULTS

Intrastromal lenticule implantation was successfully performed in all cases without any complication. Corneal thickness showed a mean enhancement of 100.4 µm at the thinnest point. On biomicroscopy, all corneas were clear at 1 year postoperatively and there was a significant improvement in corneal densitometry during the entire follow-up period. Confocal biomicroscopy showed collagen reactivation without any inflammatory features caused by the implanted fresh lenticules. CDVA improved from 0.70 to 0.49 logMAR (P = .001) and keratometry decreased from 54.68 ± 2.77 to 51.95 ± 2.21 diopters (P = .006).

CONCLUSIONS

Customized SMILE lenticule implantation by femtosecond laser proved to be feasible, resulting in an improvement in vision, topography, and refraction in the implanted eyes. [J Refract Surg. 2020;36(12):786-794.].

Для цитирования: Doroodgar Farideh, Jabbarvand Mahmoud, Niazi Sana, Karimian Farid, Niazi Feizollah, Sanginabadi Azad, Ghoreishi Mohammad, Alinia Cyrus, Hashemi Hassan, Alió Jorge L. Customized Stromal Lenticule Implantation for Keratoconus.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2020. DOI: 10.3928/1081597x-20201005-01.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.