Journal of cataract and refractive surgery · 2021
Clinical evaluation of the effectiveness of asymmetric intracorneal ring with variable thickness and width for the management of keratoconus.
СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Cuiña Sardiña Ricardo, Arango Alexandra, Alfonso Jose F, Álvarez de Toledo Juan, Piñero David P
Аннотация
PURPOSE: To evaluate the short-term clinical outcomes obtained with a new model of asymmetric intracorneal ring segments (ICRS) with variable thickness and base width in keratoconus.
SETTING: Four ophthalmologic centers in Spain.
DESIGN: Prospective multicenter longitudinal noncomparative clinical trial.
METHODS: Thirty-one keratoconus eyes of 25 patients (aged 15 to 50 years) that underwent implantation of ICRS of variable thickness and base (AJL-pro+) in 4 Spanish centers were enrolled. Visual, refractive, topographic, aberrometric, and pachymetric changes were evaluated during a 3-month follow-up. Complications were also recorded.
RESULTS: Statistically significant changes after surgery were observed in uncorrected distance visual acuity (P = .002) and corrected distance visual acuity (CDVA) (P = .005), as well as in spherical equivalent (P = .006). At 3 months postoperatively, no loss of 2 or more lines of CDVA was observed, whereas 48.4% (15) of eyes gained ≥1 line. Statistically significant changes were observed in the steepest and mean keratometric values (P ≤ .047) and in the magnitude of astigmatism (P < .001) of both anterior and posterior corneal surfaces. Likewise, a change to a less prolate shape of the anterior surface was found (P = .011). Primary coma was also reduced significantly at 1 month postoperatively (P = .001, mean reduction 40.1%). No serious implant-related complications occurred during the follow-up.
CONCLUSIONS: The implantation of intrastromal asymmetric ring segments of variable thickness and base width in keratoconus corneas induces a significant anterior corneal flattening, leading to refractive changes, a significant reduction of its prolate shape and irregularity, and improvement in patient CDVA.
SETTING: Four ophthalmologic centers in Spain.
DESIGN: Prospective multicenter longitudinal noncomparative clinical trial.
METHODS: Thirty-one keratoconus eyes of 25 patients (aged 15 to 50 years) that underwent implantation of ICRS of variable thickness and base (AJL-pro+) in 4 Spanish centers were enrolled. Visual, refractive, topographic, aberrometric, and pachymetric changes were evaluated during a 3-month follow-up. Complications were also recorded.
RESULTS: Statistically significant changes after surgery were observed in uncorrected distance visual acuity (P = .002) and corrected distance visual acuity (CDVA) (P = .005), as well as in spherical equivalent (P = .006). At 3 months postoperatively, no loss of 2 or more lines of CDVA was observed, whereas 48.4% (15) of eyes gained ≥1 line. Statistically significant changes were observed in the steepest and mean keratometric values (P ≤ .047) and in the magnitude of astigmatism (P < .001) of both anterior and posterior corneal surfaces. Likewise, a change to a less prolate shape of the anterior surface was found (P = .011). Primary coma was also reduced significantly at 1 month postoperatively (P = .001, mean reduction 40.1%). No serious implant-related complications occurred during the follow-up.
CONCLUSIONS: The implantation of intrastromal asymmetric ring segments of variable thickness and base width in keratoconus corneas induces a significant anterior corneal flattening, leading to refractive changes, a significant reduction of its prolate shape and irregularity, and improvement in patient CDVA.