m+Medelevator.RU
← Поиск публикаций
Journal of cataract and refractive surgery · 2021

Evaluating keratoconus progression prior to crosslinking: maximum keratometry vs the ABCD grading system.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Vinciguerra Riccardo, Belin Michael W, Borgia Alfredo, Piscopo Raffaele, Montericcio Alessio, Confalonieri Filippo, Legrottaglie Emanuela F, Rosetta Pietro, Vinciguerra Paolo

Аннотация

PURPOSE: To evaluate the correlation between changes in maximum keratometry (Kmax) and ABC values from the ABCD Progression Display (Pentacam) in progressive keratoconus (KC) and to evaluate whether the ABC changes were able to detect progression earlier than Kmax.

SETTING: Humanitas Clinical and Research Center, Rozzano, Milan, Italy.

DESIGN: Retrospective study.

METHODS: Kmax, ABC values, and thinnest point (ThCT) were recorded at the day of corneal crosslinking (CXL) (T0) and previous follow-up (T-1). In patients without earlier progression in Kmax, follow-up examination (T-2) was used to determine whether any of the ABC parameters reached statistical significance for progression.

RESULTS: Seventy-six eyes of 63 patients scheduled for CXL with documented progression (Kmax increase of >1.00 diopter) were included. There was a significant, albeit moderate, correlation between the change in Kmax between T0 and T-1 and the change in both A (ρ = 0.391) and B values (ρ = 0.339). There was no significant correlation between the change in Kmax between T0 and T-1 and the change in either C or ThCT. In patients with T-2 examinations, 16 (51.6%) of 31 patients showed a statistically significant change on the ABCD progression display that was not detected with Kmax.

CONCLUSIONS: This study showed a significant, but moderate, correlation between the change in Kmax and the change in A and B values in progressive KC. Moreover, more than half of the cases showed documented progression earlier with the ABCD progression display than that detected by standard Kmax changes. This study suggests possible changes in progression criteria to allow for earlier intervention.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты