MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1310/hp8b-nf27-vfwa-80yx

Медицинская библиотека · HIV clinical trials · 2002

Granulocyte-macrophage colony-stimulating factor (GM-CSF) restores allostimulatory function to accessory cells in patients with AIDS.

Bernstein Zale P, Brooks Stephen P, Chanan-Khan Asher, Gollnick Sandra O, Gilbert Mark J, Miller Kena C, Tomasi Thomas B

Клиническое исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Impaired allostimulatory function of dendritic cells in patients with AIDS has been reported previously. Granulocyte-macrophage colony-stimulating factor (GM-CSF) can restore the T-cell stimulatory function in transforming growth factor-beta 1 (TGF-beta 1)-inhibited murine accessory cells. We now report the effect of intravenous recombinant human GM-CSF (rhGM-CSF) on accessory cells of HIV-infected patients.

METHOD: The in vivo effect of GM-CSF on allostimulatory function of accessory cells was evaluated. Seventeen individuals with AIDS received a single infusion of rhGM-CSF (125 mg/m(2) over 120 minutes). Samples of peripheral blood lymphocytes (PBL) were taken at 1, 5, and 24 hours after infusion, and the allostimulatory capacity was measured.

RESULTS

A single bolus infusion of rhGM-CSF resulted in significantly increased accessory cell function in 13/17 (88%) patients at one or more assayed time points after infusion.

CONCLUSION

These results suggest that the administration of rhGM-CSF can potentially restore allostimulatory function to accessory cells in HIV-infected patients, and this presents a novel way of immune reconstitution. Clinical significance of this approach of immune reconstitution in AIDS patients warrants further investigations.

Для цитирования: Bernstein Zale P, Brooks Stephen P, Chanan-Khan Asher, Gollnick Sandra O, Gilbert Mark J, Miller Kena C, Tomasi Thomas B. Granulocyte-macrophage colony-stimulating factor (GM-CSF) restores allostimulatory function to accessory cells in patients with AIDS.. HIV clinical trials. 2002. DOI: 10.1310/hp8b-nf27-vfwa-80yx.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.