Precorneal residence time of artificial tears measured in dry eye subjects.

Paugh Jerry R, Nguyen Andrew Loc, Ketelson Howard A, Christensen Mike T, Meadows David L

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: The purpose of this investigation was to measure the precorneal residence time of saline and five marketed artificial tears in dry eye subjects using fluorometry.

METHODS

FITC-dextran, 70 kDa molecular weight, was admixed under sterile conditions (0.1% wt/vol) into buffered saline and the marketed artificial tear formulations of varying viscosity. Precorneal residence time (RT) was measured directly in 16 mild to moderate dry eye subjects, classified by sub-type, in a six-way cross-over, masked and randomized study. FITC-dextran tracer decay with a scanning fluorometer was used to estimate the gross RT (i.e., the time in minutes for the signal to return to baseline).

RESULTS

All subjects were classified as having non-inflammatory meibomian gland dysfunction except one, who had a mixture of aqueous deficiency and meibomian gland dysfunction. In two separate determinations, the saline RTs were 19.1 +/- 7.4 and 17.6 +/- 8.2 min. The RTs for the formulations varied to some degree by viscosity, with two higher viscosity formulations demonstrating the longest RTs of 36 to 41 min, approximately twice that of saline (p < 0.001 for both 0.4% polyethylene glycol/0.3% propylene glycol, and 1.0% carboxymethylcellulose). An oil emulsion, low viscosity carboxymethylcellulose and moderate viscosity hydroxypropylmethylcellulose-containing formulation were not statistically different from saline (RTs of 18, 22 and 24 min, p values = 0.983, 0.818 and 0.099, respectively).

CONCLUSIONS

More than two-fold RT differences were found for the higher viscosity, more muco-adhesive formulations compared to saline. However, other formulations provided RTs close to saline, suggesting that RT is influenced by factors other than simple viscosity. Future studies should examine the interplay of spreading characteristics, pseudoplasticity and muco-adhesion relative to RT to determine the individual and cumulative effects on formulation retention.

Для цитирования: Paugh Jerry R, Nguyen Andrew Loc, Ketelson Howard A, Christensen Mike T, Meadows David L. Precorneal residence time of artificial tears measured in dry eye subjects.. Optometry and vision science : official publication of the American Academy of Optometry. 2008. DOI: 10.1097/opx.0b013e3181824de3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.