MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.anl.2007.03.004

Медицинская библиотека · Auris, nasus, larynx · 2007

Studies on the relationship between electrogustometry and sour taste perception.

Ellegård Eva K, Goldsmith David, Hay K David, Stillman Jennifer A, Morton Randall P

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

Electrogustometry is used as a measurement of taste perception. The prevailing theory is that the anodal current delivered to the tongue mucosa stimulates the sour taste receptors, but this is not universally accepted. Our aim was to evaluate to what extent electrogustometry relates to an ability to detect sour taste--rather than sweet, salt, or bitter.

METHODS

We compared automated electrogustometric thresholds with visual analogue scale (VAS) ratings of various tastant solutions in 114 subjects. The whole mouth, and each side of the tongue were tested separately. VAS scores from the strongest set of solutions, and the lowest electrogustometry thresholds for each location were used for statistics.

RESULTS

There was a significant correlation between electrogustometry threshold and the whole mouth perception of the salt taste solution. Electrogustometry correlated significantly but weakly for all taste qualities when testing was confined to left and right oral tongue. The positive predictive values of electrogustometry were no better in relation to sour taste perception than to the other taste qualities.

CONCLUSIONS

Our results do not support the theory that electrogustometry is mediated by sour taste receptors or even that it reflects the sour taste quality. We postulate that electrogustometry measures a function of taste perception, which is different from that induced by chemical stimuli.

Для цитирования: Ellegård Eva K, Goldsmith David, Hay K David, Stillman Jennifer A, Morton Randall P. Studies on the relationship between electrogustometry and sour taste perception.. Auris, nasus, larynx. 2007. DOI: 10.1016/j.anl.2007.03.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.