MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-022-08601-0

Медицинская библиотека · European radiology · 2022

Prediction of high-risk esophageal varices in patients with chronic liver disease with point and 2D shear wave elastography: a systematic review and meta-analysis.

Liu Yue, Tan Hao-Yan, Zhang Xiao-Guang, Zhen Yan-Hua, Gao Fan, Lu Xue-Feng

СтатьяМетаанализСистематический обзорПеревод пока не подготовлен

Аннотация

OBJECTIVE

To assess the diagnostic performance of liver stiffness (LS) and spleen stiffness (SS) measured by point shear wave elastography (pSWE) and 2D shear wave elastography (2D-SWE) in the detection of high-risk esophageal varices (HREV) and to compare their diagnostic accuracy.

METHODS

Through systematic search of PubMed, Embase, and Web of Science databases, we included 17 articles reporting the diagnostic performance of LS or SS measured by pSWE or 2D-SWE for HREV. We used a bivariate random-effects model to estimate pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), area under summary receiver operator characteristic curve (AUSROC), and diagnostic odds ratio (DOR).

RESULTS

For LS, there was no significant difference between the pooled sensitivity, 0.89 (95% confidence interval CI, 0.81-0.94) vs. 0.8 (95% CI, 0.72-0.86) (p = 0.13), and specificity, 0.81 (95% CI, 0.73-0.87) vs. 0.73 (95% CI, 0.65-0.79) (p = 0.07) of pSWE and 2D-SWE. The AUSROC and DOR of pSWE were higher than those of 2D-SWE: 0.92 (95% CI, 0.89-0.94) vs. 0.84 (95% CI, 0.80-0.87), p = 0.03, 33 (95% CI, 25-61) vs. 11 (95% CI, 5-22), (p < 0.01). For SS, there was no significant difference between the pooled sensitivity 0.91 (95% CI, 0.78-0.96) vs. 0.89 (95% CI, 0.80-0.94) (p = 0.43); specificity, 0.79 (95% CI, 0.72-0.84) vs. 0.72 (95% CI, 0.63-0.79) (p = 0.06); and DOR, 35 (95% CI, 13-100) vs. 20 (95% CI, 8-50) (p = 0.16) of pSWE and 2D-SWE.

CONCLUSION

LS and SS measured by pSWE and 2D-SWE have good accuracy in predicting HREV.

KEY POINTS: • There is modest difference between the diagnostic performance of LS and SS measured by pSWE and 2D-SWE. • LS and SS measured by pSWE and 2D-SWE both have high sensitivity, specificity, and AUSROC for the evaluation of HREV in patients with CLD. • pSWE and 2D-SWE are promising tools for noninvasive monitoring risk of esophageal varices bleeding of CLD patients.

Для цитирования: Liu Yue, Tan Hao-Yan, Zhang Xiao-Guang, Zhen Yan-Hua, Gao Fan, Lu Xue-Feng. Prediction of high-risk esophageal varices in patients with chronic liver disease with point and 2D shear wave elastography: a systematic review and meta-analysis.. European radiology. 2022. DOI: 10.1007/s00330-022-08601-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.