MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/01.icl.0000181819.63425.a6

Медицинская библиотека · Eye & contact lens · 2006

Comparison of initial treatment response to two enhanced-viscosity artificial tears.

Noecker Robert J

Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the effectiveness of 1.0% carboxymethylcellulose (CMC) (Refresh Liquigel, Allergan, Inc., Irvine, CA) and propylene glycol/polyethylene glycol 400 (PG-HPG) (Systane, Alcon, Fort Worth, TX) in providing relief of dry eye symptoms and signs.

METHODS

To evaluate patient comfort and drop preference, patients were given CMC in one eye and PG-HPG in the other. Five minutes after the initial drop application, patients were questioned on overall preference and comfort, as measured by stickiness, blurring, and soothing. Patients were then randomized to receive CMC or PG-HPG in both eyes for 1 week. Fluorescein staining was evaluated at baseline and week 1.

RESULTS

Of patients with a preference, more patients preferred CMC than PG-HPG. Thirty-six percent preferred CMC, and 24% preferred PG-HPG. More (35%) patients found CMC to be more soothing than PG-HPG (22%). After 1 week of treatment, eyes treated with CMC consistently showed less ocular surface staining than did eyes treated with PG-HPG. Mean corneal staining score in the inferior region was significantly lower in the CMC group than in the PG-HPG group (P = 0.008) at week 1. CMC provided a statistically significant decrease in mean corneal inferior staining (P < 0.001), whereas the PG-HPG group (P = 0.185) had no significant change. In the temporal conjunctival region, CMC provided a significantly lower mean staining score than PG-HPG after 1 week of treatment (P = 0.005).

CONCLUSIONS

Patients found CMC to be more comfortable than PG-HPG. After 1 week of use, CMC provided greater relief of dry eye signs and symptoms than PG-HPG.

Для цитирования: Noecker Robert J. Comparison of initial treatment response to two enhanced-viscosity artificial tears.. Eye & contact lens. 2006. DOI: 10.1097/01.icl.0000181819.63425.a6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.