Journal of the Saudi Heart Association · 2025
Impact of Transcatheter Aortic Valve Implantation (TAVI) on Left Ventricular Mass, Volumes, and Pressure. A Single-center Echocardiographic Analysis.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Alshammari Fouad T, Alonazi Afrah A, Almutairi Mohammed D, Majrashi Khaled A, Almutairi Atheer M, Shah Muhammad A
Аннотация
BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an alternative treatment for surgically high-risk patients with severe aortic stenosis (AS). This study aimed to assess the echocardiographic outcomes of TAVI in patients with severe AS, focusing on left ventricular mass, volume, and pressure.
METHODS: This retrospective, registry-based, single-center study was conducted at King Salman Heart Center, Riyadh, Saudi Arabia. We included 200 adult patients who underwent the TAVI procedure and completed at least one year of clinical and echocardiographic follow-up. Baseline demographic, clinical, and echocardiographic data were collected and paired pre- and post-procedure echocardiographic measurements were analyzed.
RESULT: Paired analysis in comparison of pre and post-transcatheter aortic valve implantation (TAVI) shows significant improvement in left ventricular (LV) mass, volume, and pressure.
CONCLUSION: This study demonstrates that transcatheter aortic valve implantation (TAVI) leads to significant improvement in key echocardiographic parameters such as left ventricular (LV) size, functions, mass, and ejection fractions (EF).
METHODS: This retrospective, registry-based, single-center study was conducted at King Salman Heart Center, Riyadh, Saudi Arabia. We included 200 adult patients who underwent the TAVI procedure and completed at least one year of clinical and echocardiographic follow-up. Baseline demographic, clinical, and echocardiographic data were collected and paired pre- and post-procedure echocardiographic measurements were analyzed.
RESULT: Paired analysis in comparison of pre and post-transcatheter aortic valve implantation (TAVI) shows significant improvement in left ventricular (LV) mass, volume, and pressure.
CONCLUSION: This study demonstrates that transcatheter aortic valve implantation (TAVI) leads to significant improvement in key echocardiographic parameters such as left ventricular (LV) size, functions, mass, and ejection fractions (EF).