Clinical utility of maximum blink interval measured by smartphone application DryEyeRhythm to support dry eye disease diagnosis.

Fujio Kenta, Nagino Ken, Huang Tianxiang, Sung Jaemyoung, Akasaki Yasutsugu, Okumura Yuichi, Midorikawa-Inomata Akie, Fujimoto Keiichi, Eguchi Atsuko, Miura Maria, Hurramhon Shokirova, Yee Alan, Hirosawa Kunihiko, Ohno Mizu, Morooka Yuki, Murakami Akira, Kobayashi Hiroyuki, Inomata Takenori

Наблюдательное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The coronavirus disease (COVID-19) pandemic has emphasized the paucity of non-contact and non-invasive methods for the objective evaluation of dry eye disease (DED). However, robust evidence to support the implementation of mHealth- and app-based biometrics for clinical use is lacking. This study aimed to evaluate the reliability and validity of app-based maximum blink interval (MBI) measurements using DryEyeRhythm and equivalent traditional techniques in providing an accessible and convenient diagnosis. In this single-center, prospective, cross-sectional, observational study, 83 participants, including 57 with DED, had measurements recorded including slit-lamp-based, app-based, and visually confirmed MBI. Internal consistency and reliability were assessed using Cronbach's alpha and intraclass correlation coefficients. Discriminant and concurrent validity were assessed by comparing the MBIs from the DED and non-DED groups and Pearson's tests for each platform pair. Bland-Altman analysis was performed to assess the agreement between platforms. App-based MBI showed good Cronbach's alpha coefficient, intraclass correlation coefficient, and Pearson correlation coefficient values, compared with visually confirmed MBI. The DED group had significantly shorter app-based MBIs, compared with the non-DED group. Bland-Altman analysis revealed minimal biases between the app-based and visually confirmed MBIs. Our findings indicate that DryEyeRhythm is a reliable and valid tool that can be used for non-invasive and non-contact collection of MBI measurements, which can assist in accessible DED detection and management.

Для цитирования: Fujio Kenta, Nagino Ken, Huang Tianxiang, Sung Jaemyoung, Akasaki Yasutsugu, Okumura Yuichi, Midorikawa-Inomata Akie, Fujimoto Keiichi, Eguchi Atsuko, Miura Maria, Hurramhon Shokirova, Yee Alan, Hirosawa Kunihiko, Ohno Mizu, Morooka Yuki, Murakami Akira, Kobayashi Hiroyuki, Inomata Takenori. Clinical utility of maximum blink interval measured by smartphone application DryEyeRhythm to support dry eye disease diagnosis.. Scientific reports. 2023. DOI: 10.1038/s41598-023-40968-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.