m+Medelevator.RU
← Поиск публикаций
European heart journal. Imaging methods and practice · 2025

Valve type and post-dilation impact on transprosthetic gradients in patients undergoing transcatheter aortic valve-in-valve procedure.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Muratori Manuela, Fusini Laura, Tamborini Gloria, Gripari Paola, Ghulam Ali Sarah, Mantegazza Valentina, Garlaschè Anna, Doni Francesco, Baggiano Andrea, Cannata Francesco, Del Torto Alberico, Fazzari Fabio, Frappampina Antonio, Junod Daniele, Maragna Riccardo, Mushtaq Saima, Tassetti Luigi, Volpe Alessandra, Galli Stefano, Fabbiocchi Franco, Gennari Marco, Agrifoglio Marco, Bartorelli Antonio L, De Marco Federico, Pepi Mauro, Pontone Gianluca

Аннотация

AIMS: Valve-in-Valve transcatheter aortic valve replacement (ViV-TAVR) is an appealing treatment option for patients with degenerated aortic bioprosthetic valves. However, higher post-procedural transprosthetic gradients are more common after ViV-TAVR than after TAVR for native aortic valve stenosis. We sought to evaluate the impact of type of implanted valve and balloon post-dilation on echocardiographic results and mortality in ViV-TAVR patients.

METHODS AND RESULTS: One hundred and eleven consecutive patients were enrolled. A balloon-expandable valve, a self-expandable valve without balloon post-dilation, and a self-expandable valve with balloon post-dilation were performed in 35 (Group 1), 39 (Group 2), and 37 (Group 3) patients, respectively. All patients underwent comprehensive transthoracic echocardiography at baseline, discharge, and 6-12 months follow-up. Successful ViV-TAVR was performed in 110 patients (99%). Baseline transprosthetic gradients, left ventricular volumes, ejection fraction, and pulmonary artery systolic pressure were similar among groups. All groups experienced a significant reduction in post-procedural gradients at discharge and during the 6-12 months follow-up compared with baseline. At discharge, the lowest mean gradient was observed in Group 3 (12 ± 7 mmHg) compared with both Group 1 (20 ± 9 mmHg) and Group 2 (17 ± 8 mmHg, P = 0.001). This result was confirmed at 6-12 months follow-up (P = 0.012). Similar 5-year all-cause mortality was observed among groups (34%, 36%, 14%, respectively, P = 0.056).

CONCLUSION: In patients with failed surgical aortic prosthesis, ViV-TAVR is an effective treatment option associated with sustained improved haemodynamics regardless of transcatheter valve type and use of balloon post-dilation. However, self-expandable valves with balloon post-dilation showed lower transprosthetic gradients.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты