MedElevator Войти в исследования
← Поиск публикаций

DOI 10.14744/anatoljcardiol.2025.5124

Медицинская библиотека · Anatolian journal of cardiology · 2025

Self-Expanding Transcatheter Aortic Valve Implantation in Patients with Severe Aortic Stenosis Undergoing Prosthetic Mitral Valve Replacement: A Single-Center Experience.

Kıvrak Ahmet, Ateş Ahmet Hakan, Menemencioğlu Can, Doğan Mert, Şahiner Mehmet Levent, Kaya Ergün Barış, Aytemir Kudret

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Following the encouraging results of several registries and trials, transcatheter aortic valve implantation has become standard therapy for aortic stenosis patients with intermediate or high operative risk for surgical treatment. Good procedural success and good clinical outcomes have been shown, but very limited data exist on transcatheter aortic valve implantation in the setting of a preexisting mitral valve (MV) prosthesis regarding the technique, potential complications, and outcomes. Single-center experience is presented with this special patient cohort.

METHODS

Here, 31 cases of transfemoral transcatheter aortic valve implantation with a self-expanding bioprosthesis (CoreValve and Evolut R; Medtronic, Minneapolis, MN, USA) in patients who had previously undergone MV surgery have been reported. Preprocedural, intraprocedural, and post-procedural outcomes and data were analyzed.

RESULTS

Between February 2013 and December 2023, 31 patients with prior MV prostheses were included. The average age was 68.7 years, and 77.4% were female. Mechanical MV prostheses were present in 90.3% of patients. The mean Society of Thoracic Surgeon score was 9.03. Transcatheter aortic valve implantation was performed 14.75 years after MV replacement. Post-procedural complications included access site issues in 25.8% of patients, with 22.5% requiring pacemaker implantation. No procedural mortality occurred. Six out of 31 patients (n = 6/31 patients) died during follow-up, primarily due to respiratory complications, and the mean survival time was 74.9 ± 8.4 months (95% CI: 58.4-91.4).

CONCLUSION

The experiences showed that transfemoral implantation of a self-expanding aortic valve with MV prostheses patients, via the transfemoral route, is safe and feasible, with maintained long-term results.

Для цитирования: Kıvrak Ahmet, Ateş Ahmet Hakan, Menemencioğlu Can, Doğan Mert, Şahiner Mehmet Levent, Kaya Ergün Barış, Aytemir Kudret. Self-Expanding Transcatheter Aortic Valve Implantation in Patients with Severe Aortic Stenosis Undergoing Prosthetic Mitral Valve Replacement: A Single-Center Experience.. Anatolian journal of cardiology. 2025. DOI: 10.14744/anatoljcardiol.2025.5124.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.