A virtual patient model for mechanical ventilation.

Morton S E, Dickson J, Chase J G, Docherty P, Desaive T, Howe S L, Shaw G M, Tawhai M

СтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVES

Mechanical ventilation (MV) is a primary therapy for patients with acute respiratory failure. However, poorly selected ventilator settings can cause further lung damage due to heterogeneity of healthy and damaged alveoli. Varying positive-end-expiratory-pressure (PEEP) to a point of minimum elastance is a lung protective ventilator strategy. However, even low levels of PEEP can lead to ventilator induced lung injury for individuals with highly inflamed pulmonary tissue. Hence, models that could accurately predict peak inspiratory pressures after changes to PEEP could improve clinician confidence in attempting potentially beneficial treatment strategies.

METHODS

This study develops and validates a physiologically relevant respiratory model that captures elastance and resistance via basis functions within a well-validated single compartment lung model. The model can be personalised using information available at a low PEEP to predict lung mechanics at a higher PEEP. Proof of concept validation is undertaken with data from four patients and eight recruitment manoeuvre arms.

RESULTS

Results show low error when predicting upwards over the clinically relevant pressure range, with the model able to predict peak inspiratory pressure with less than 10% error over 90% of the range of PEEP changes up to 12 cmH2O.

CONCLUSIONS

The results provide an in-silico model-based means of predicting clinically relevant responses to changes in MV therapy, which is the foundation of a first virtual patient for MV.

Для цитирования: Morton S E, Dickson J, Chase J G, Docherty P, Desaive T, Howe S L, Shaw G M, Tawhai M. A virtual patient model for mechanical ventilation.. Computer methods and programs in biomedicine. 2018. DOI: 10.1016/j.cmpb.2018.08.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.