m+Medelevator.RU
← Поиск публикаций
Indian journal of critical care medicine : peer-reviewed, official publication of Indian Society of Critical Care Medicine · 2018

Targeted-Volume Noninvasive Ventilation Reduces Extubation Failure in Postextubated Medical Intensive Care Unit Patients: A Randomized Controlled Trial.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Thanthitaweewat Vorawut, Muntham Dittapol, Chirakalwasan Naricha

Аннотация

PURPOSE: Till date, the benefit of using noninvasive ventilation (NIV) routinely after extubation to prevent reintubation has been conflicting. We aim to demonstrate the effect of targeted-volume NIV for the prevention of reintubation and extubation failure after planned extubation in medical intensive care unit (ICU) patients.

STUDY DESIGN: This was a prospective, randomized controlled study.

MATERIALS AND METHODS: Patients on invasive mechanical ventilation for more than 48 hrs for acute respiratory failure, who were ready for extubation, were randomized into targeted-volume NIV (intervention group) or oxygen mask (controlled group) immediately after extubation and continuously for 24 hrs.

RESULTS: A total of 58 patients were enrolled in this study. The targeted-volume NIV group was observed to have a trend toward lower reintubation rate within 48 hrs compared to oxygen mask group (0% vs. 17.2%; P = 0.052). Extubation failure rate within 48 hrs was significantly lower in targeted-volume NIV group compared to oxygen mask group (0% vs. 41.38%; P < 0.001). There was a trend toward lower ICU length of stay (6[5] days vs. 10[8] days (median interquartile range [IQR]); P = 0.053) as well as shorter hospital length of stay after extubation (10[19] days vs. 18[15] days (median [IQR]); P = 0.059). There were no differences in the incidence of ventilator-associated pneumonia (VAP)/hospital-acquired pneumonia (HAP) (6.90% vs. 20.69%;P = 0.253) and 28 day-mortality (13.79% vs. 20.69%; P = 0.487).

CONCLUSIONS: Our study is the first study to demonstrate the benefit of application of targeted-volume NIV immediately after extubation in reducing extubation failure rate. There was a trend toward lowering reintubation rate and shorter ICU length of stay and hospital length of stay after extubation in mixed medical ICU patients.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты