MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000336174

Медицинская библиотека · Digestion · 2012

Comparison of lactulose and glucose breath test for diagnosis of small intestinal bacterial overgrowth in patients with irritable bowel syndrome.

Rana S V, Sharma S, Kaur J, Sinha S K, Singh K

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND AND AIMS: Validity of the lactulose breath test (LBT) to diagnose small intestinal bacterial overgrowth (SIBO) has been questioned. Therefore, a study was planned to compare LBT with glucose breath test (GBT) to diagnose SIBO in irritable bowel syndrome (IBS) patients and controls.

METHODS

175 diarrhea-predominant IBS patients and 150 apparently healthy controls were enrolled. IBS was diagnosed according to Rome II criteria. Breath samples were collected every 10 min up to 180 min. Breath H₂ and CH₄ were measured using an SC MicroLyzer. SIBO was positive with a sustained increase in breath H₂ or CH₄ or both ≥10 ppm over a baseline value within <90 min in case of LBT and within <120 min in GBT.

RESULTS

SIBO was positive in 60/175 (34.3%) patients by lactulose and in 11/175 (6.2%) patients by GBT. In controls, LBT was positive for SIBO in 45/150 (30%) patients and in 1/150 (0.66%) patients by GBT. Positive LBT for SIBO was not significantly different in patients and controls; while using GBT, SIBO was significantly higher (p < 0.01) in patients as compared to controls. By using GBT as gold standard for SIBO, sensitivity, specificity, positive predictive value and negative predictive value of LBT in IBS patients was 63.6, 67.7, 11.7 and 96.6% respectively.

CONCLUSION

LBT is not a good test to discriminate SIBO in IBS patients from controls.

Для цитирования: Rana S V, Sharma S, Kaur J, Sinha S K, Singh K. Comparison of lactulose and glucose breath test for diagnosis of small intestinal bacterial overgrowth in patients with irritable bowel syndrome.. Digestion. 2012. DOI: 10.1159/000336174.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.