Ampulary tumors: presurgical staging by endoscopic ultrasonography. Diagnostic test study.
Аннотация
OBJECTIVE
To analyze the accuracy of endoscopic ultrasound (EUS) in the evaluation of ampullary tumors compared to histopathology (HP) staging.
METHODS
A retrospective diagnostic test study. Patients with ampullary tumors staged by EUS and postpancreatoduodenectomy HP attended during 2012-2018 at tertiary level hospital.
RESULTS
14 patients with adenocarcinoma where included. Tumor size measured by EUS showed an adequate correlation (R = 0.65; p= 0.01) with HP. The accuracy in the evaluation of duodenal wall, pancreatic, and biliary duct invasion was 78.5, 78.5 and 57.1%, respectively. By HP, there were three T1 (21.4%), two T2 (14.2%) and nine T3 (64.2%). The accuracy of T and N staging by EUS was 71.4% (kappa = 0.50) and 50% (kappa = -0.04) respectively. There were more staging errors in patients with biliary stent.
CONCLUSION
EUS was useful in estimating tumor size, duodenal wall and pancreatic invasion. Limitation was found in the evaluation of biliary duct invasion, as well as overestimation of T stage and underestimation of N stage. It is necessary an increased effort in ultrasonography training. We suggest EUS testing before biliary stenting.