MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12938-015-0060-2

Медицинская библиотека · Biomedical engineering online · 2015

Optimizing parameters of an open-source airway segmentation algorithm using different CT images.

Nardelli Pietro, Khan Kashif A, Corvò Alberto, Moore Niamh, Murphy Mary J, Twomey Maria, O'Connor Owen J, Kennedy Marcus P, Estépar Raúl San José, Maher Michael M, Cantillon-Murphy Pádraig

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Computed tomography (CT) helps physicians locate and diagnose pathological conditions. In some conditions, having an airway segmentation method which facilitates reconstruction of the airway from chest CT images can help hugely in the assessment of lung diseases. Many efforts have been made to develop airway segmentation algorithms, but methods are usually not optimized to be reliable across different CT scan parameters.

METHODS

In this paper, we present a simple and reliable semi-automatic algorithm which can segment tracheal and bronchial anatomy using the open-source 3D Slicer platform. The method is based on a region growing approach where trachea, right and left bronchi are cropped and segmented independently using three different thresholds. The algorithm and its parameters have been optimized to be efficient across different CT scan acquisition parameters. The performance of the proposed method has been evaluated on EXACT'09 cases and local clinical cases as well as on a breathing pig lung phantom using multiple scans and changing parameters. In particular, to investigate multiple scan parameters reconstruction kernel, radiation dose and slice thickness have been considered. Volume, branch count, branch length and leakage presence have been evaluated. A new method for leakage evaluation has been developed and correlation between segmentation metrics and CT acquisition parameters has been considered.

RESULTS

All the considered cases have been segmented successfully with good results in terms of leakage presence. Results on clinical data are comparable to other teams' methods, as obtained by evaluation against the EXACT09 challenge, whereas results obtained from the phantom prove the reliability of the method across multiple CT platforms and acquisition parameters. As expected, slice thickness is the parameter affecting the results the most, whereas reconstruction kernel and radiation dose seem not to particularly affect airway segmentation.

CONCLUSION

The system represents the first open-source airway segmentation platform. The quantitative evaluation approach presented represents the first repeatable system evaluation tool for like-for-like comparison between different airway segmentation platforms. Results suggest that the algorithm can be considered stable across multiple CT platforms and acquisition parameters and can be considered as a starting point for the development of a complete airway segmentation algorithm.

Для цитирования: Nardelli Pietro, Khan Kashif A, Corvò Alberto, Moore Niamh, Murphy Mary J, Twomey Maria, O'Connor Owen J, Kennedy Marcus P, Estépar Raúl San José, Maher Michael M, Cantillon-Murphy Pádraig. Optimizing parameters of an open-source airway segmentation algorithm using different CT images.. Biomedical engineering online. 2015. DOI: 10.1186/s12938-015-0060-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.