MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/rct.0000000000000218

Медицинская библиотека · Journal of computer assisted tomography · 2015

Comparison of a New Integral-Based Half-Band Method for CT Measurement of Peripheral Airways in COPD With a Conventional Full-Width Half-Maximum Method Using Both Phantom and Clinical CT Images.

Cho Young Hoon, Seo Joon Beom, Kim Namkug, Lee Hyun Joo, Hwang Hye Jeon, Kim Eun Young, Oh Sang Young

Сравнительное исследованиеОценочное исследованиеСтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

To compare a new integral-based half-band method (IBHB) and a conventional full-width half-maximum (FWHM) method in measuring peripheral airway dimensions at airway phantoms and thin-section computed tomography of chronic obstructive pulmonary disease (COPD).

METHODS

The IBHB was validated and compared using airway phantoms and 50 patients with COPD. Airway parameters (wall area percentage [WA%], mean lumen radius, and mean wall thickness) were measured at fourth to sixth generations of the right apical bronchus. Matched results from 2 methods were compared and correlated with forced expiratory volume (FEV) in 1 second (FEV1), FEV1 / forced vital capacity (FVC), and global initiative for chronic obstructive lung disease (GOLD) stage. Linear regression analysis was performed using airway dimensions and emphysema index.

RESULTS

The IBHB generated more accurate measurements at phantom study. Measured airway parameters by both methods at thin-section computed tomography study were significantly different (all P < 0.05, paired t test). The IBHB method-measured WA% and wall thickness were significantly smaller. Mean WA% with IBHB also showed better correlation than that with FWHM (FEV1, r = -0.52 vs -0.28; FEV1 / FVC, r = -0.41 vs r = -0.20; GOLD, 0.52 vs 0.33, respectively). Linear regression analysis revealed fifth-generation WA% measured by IBHB was an independent variable, and addition to emphysema index increased predictability (FEV1, r = 0.63; FEV1 / FVC, r = 0.61; GOLD, r = 0.70).

CONCLUSIONS

The new IBHB measured peripheral airway dimensions differently than FWHM and showed better correlations with functional parameters in COPD.

Для цитирования: Cho Young Hoon, Seo Joon Beom, Kim Namkug, Lee Hyun Joo, Hwang Hye Jeon, Kim Eun Young, Oh Sang Young. Comparison of a New Integral-Based Half-Band Method for CT Measurement of Peripheral Airways in COPD With a Conventional Full-Width Half-Maximum Method Using Both Phantom and Clinical CT Images.. Journal of computer assisted tomography. 2015. DOI: 10.1097/rct.0000000000000218.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.