m+Medelevator.RU
← Поиск публикаций
The Journal of thoracic and cardiovascular surgery · 2020

The impact of uncorrected mild aortic insufficiency at the time of left ventricular assist device implantation.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Tanaka Yuki, Nakajima Tomohiro, Fischer Irene, Wan Fei, Kotkar Kunal, Moon Marc R, Damiano Ralph J, Masood Muhammad F, Itoh Akinobu

Аннотация

OBJECTIVE: The study objective was to investigate the progression of uncorrected mild aortic insufficiency and its impact on survival and functional status after left ventricular assist device implantation.

METHODS: We retrospectively reviewed 694 consecutive patients who underwent implantation of a continuous-flow left ventricular assist device between January 2006 and March 2018. Pre-left ventricular assist device transthoracic echocardiography identified 111 patients with mild aortic insufficiency and 493 patients with trace or no aortic insufficiency. To adjust for differences in preoperative factors, propensity score matching was used, resulting in 101 matched patients in each of the mild aortic insufficiency and no aortic insufficiency groups.

RESULTS: Although both groups showed similar survival (P = .58), the mild aortic insufficiency group experienced higher incidence of readmission caused by heart failure (hazard ratio, 2.62; 95% confidence interval, 1.42-4.69; P < .01). By using the mixed effect model, pre-left ventricular assist device mild aortic insufficiency was a significant risk factor for both moderate or greater aortic insufficiency and worsening New York Heart Association functional status (P < .01).

CONCLUSIONS: Patients with uncorrected mild aortic insufficiency had a higher risk of progression to moderate or greater aortic insufficiency after left ventricular assist device implantation with worse functional status and higher incidence of readmission caused by heart failure compared with patients without aortic insufficiency. Further investigations into the safety and efficacy of concomitant aortic valve procedures for mild aortic insufficiency at the time of left ventricular assist device implant are warranted to improve patients' quality of life, considering the longer left ventricular assist device use as destination therapy and bridge to transplant with the new US heart allocation system.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты