MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.athoracsur.2020.04.108

Медицинская библиотека · The Annals of thoracic surgery · 2020

Excellent Hemodynamic Performance After Aortic Valve Neocuspidization Using Autologous Pericardium.

Krane Markus, Boehm Johannes, Prinzing Anatol, Ziegelmueller Johannes, Holfeld Johannes, Lange Rüdiger

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Aortic valve neocuspidization (AVNeo) for trileaflet aortic valve reconstruction using autologous pericardium (Ozaki procedure) offers an alternative treatment modality to overcome drawbacks of conventional prosthetic aortic valve replacement.

METHODS

Between October 2016 and April 2019, 103 patients underwent surgery. Mean follow-up was 426 ± 270 days. Aortic stenosis was the leading diagnosis in 80 patients (77.7%) and aortic regurgitation in 23 (22.3%), respectively. Mean age was 54.0 ± 16.4 years (range, 13.8-78.5). A bicuspid valve was found in 81 patients (78.6%). Transthoracic echocardiography was performed at discharge and at 6 to 12 months after surgery. During AVNeo surgery valve sizing for an Abbott/St Jude Trifecta bioprosthesis (virtually implanted Trifecta bioprosthesis; St Jude Medical, St Paul, MN) was performed to compare pressure gradients and effective orifice area with published data.

RESULTS

Trileaflet aortic valve reconstruction was achieved in all patients. In 38 patients neocommissures were created (36.9%). Mean cross-clamp time was 135 ± 20 minutes. Four patients underwent reoperation; the overall freedom from reoperation was 96.1%. Echocardiographic 6- to 12-months follow-up after surgery was available in 93.8% of patients and did not show any change in hemodynamic parameters compared with discharge. Comparison between AVNeo and virtually implanted Trifecta Bioprosthesis revealed a significantly lower mean pressure gradient (8.5 ± 3.7 mm Hg vs 10.2 ± 2.0 mm Hg, P < .001) and higher mean effective orifice area (2.2 ± 0.7 cm2 vs 2.1 ± 0.4 cm2, P = .037) for AVNeo.

CONCLUSIONS

AVNeo shows low reoperation rates after surgery within the first 2 years. The hemodynamic performance is excellent, and the effective orifice area and mean pressure gradient remain stable within the first year.

Для цитирования: Krane Markus, Boehm Johannes, Prinzing Anatol, Ziegelmueller Johannes, Holfeld Johannes, Lange Rüdiger. Excellent Hemodynamic Performance After Aortic Valve Neocuspidization Using Autologous Pericardium.. The Annals of thoracic surgery. 2020. DOI: 10.1016/j.athoracsur.2020.04.108.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.