DOI 10.1016/j.cardfail.2020.05.013
Aortic Insufficiency During HeartMate 3 Left Ventricular Assist Device Support.
Аннотация
BACKGROUND
Aortic insufficiency (AI) is associated with morbidity and mortality in patients with continuous-flow left ventricular assist devices (LVADs), whereas its impact on the HeartMate 3 LVAD cohorts remains uninvestigated. We aimed to investigate the clinical impact of AI on patients with HeartMate 3 LVADs.
METHODS AND
RESULTS
Consecutive 61 patients (median age 54 years; 67% male) implanted with HeartMate 3 LVAD between 2015 and 2019 were enrolled and underwent echocardiography at 3 months after LVAD implantation. AI severity was quantified by the novel Doppler echocardiographic method obtained at the outflow cannula and the calculated regurgitation fraction of 30% or greater (moderate or greater) was defined as significant. At 3 months after implant, 12 patients (20%) had significant AI. They had a higher incidence of death or heart failure readmissions compared with those without significant AI during a 1-year observational period (70% vs 24%, P = .003) with an adjusted hazard ratio of 2.76 (95% confidence interval 1.03-7.88).
CONCLUSIONS
In patients with HeartMate 3 LVAD support, significant AI remains both prevalent and a clinically significant downstream complication.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.