MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.28783

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2020

3-Dimensional printing to predict paravalvular regurgitation after transcatheter aortic valve replacement.

Reiff Christopher, Zhingre Sanchez Jorge D, Mattison Lars M, Iaizzo Paul A, Garcia Santiago, Raveendran Ganesh, Gurevich Sergey

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

There is no effective method to predict paravalvular regurgitation prior to transcatheter aortic valve replacement (TAVR).

METHODS

We retrospectively analyzed pre-TAVR computed tomography (CT) scans of 20 patients who underwent TAVR for severe, calcific aortic stenosis and subsequently printed 3-dimensional (3D) aortic root models of each patient. Models were printed using Ninjaflex thermoplastic polyurethane (TPU) (Ninjatek Manheim, PA) and TPU 95A (Ultimaker, Netherlands) on Ultimaker 3 Extended 3D printer (Ultimaker, Netherlands). The models were implanted at nominal pressure with same sized Sapien balloon-expandable frames (Edwards Lifesciences, CA) as received in-vivo. Ex-vivo implanted TAVR models (eTAVR) were scanned using Siemens SOMATOM flash dual source CT (Siemens, Malvern, PA) and then analyzed with Mimics software (Materialize NV, Leuven, Belgium) to evaluate relative stent appositions. eTAVR were then compared to post-TAVR echocardiograms for each patient to assess for correlations of identified and predicted paravalvular leak (PVL) locations.

RESULTS

A total of 20 patients (70% male) were included in this study. The median age was 77.5 (74-83.5) years. Ten patients were characterized to elicit mild (9/10) or moderate (1/10) PVL, and 10 patients presented no PVL. In patients with echocardiographic PVL, eTAVR 3D model analyses correctly identified the site of PVL in 8/10 cases. In patients without echocardiographic PVL, eTAVR 3D model analyses correctly predicted the lack of PVL in 9/10 cases.

CONCLUSION

3D printing may help predict the potential locations of associated PVL post-TAVR, which may have implications for optimizing valve selection and sizing.

Для цитирования: Reiff Christopher, Zhingre Sanchez Jorge D, Mattison Lars M, Iaizzo Paul A, Garcia Santiago, Raveendran Ganesh, Gurevich Sergey. 3-Dimensional printing to predict paravalvular regurgitation after transcatheter aortic valve replacement.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2020. DOI: 10.1002/ccd.28783.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.