[Arrhythmia, device interventions and mortality analysis in patients with implanted cardioverter-defibrillator with/without resynchronisation therapy in dilative cardiomyopathy in primary prevention of sudden cardiac death].

Lelakowski Jacek, Pudło Joanna, Lelakowska-Pieła Maria, Rydlewska Anna, Piekarz Justyna, Domaracki Donat

Аннотация на английскомСтатьяПеревод пока не подготовлен

Аннотация

UNLABELLED: Ambulatory follow-up of patients with implanted cardioverter-defibrillator (ICD) with/without resynchronisation therapy (CRTD) requires regular visits to assess arrhythmias, device interventions and mortality.

AIM: The aim of the study was to examine arrhythmia prevalence, device interventions and mortality in patients with dilative cardiomyopathy with ICD/CRTD implanted in primary sudden cardiac death (SCD) prevention.

MATERIALS AND

METHODS

The study consisted of patients with ICD and/or CRTD implanted between 2010-2011. The inclusion criteria were: left ventricle ejection fraction (LVEF) ≤ 35%, NYHA class ≥ II, implantation in primary SCD prevention and in case of CRTD additionally LBBB with wide QRS ≥ 120ms. All of patients' visits in outpatient clinic were analysed. The following data were assessed: age, gender, presence of coronary artery disease (CAD), diabetes, thyroid gland diseases, chronic kidney failure, atrial fibrillation (AF), LVEF, NYHA class, device interventions, number of arrhythmias, changes in pharmacotherapy, device parameters and mortality.

RESULTS

The study analysed 360 patients (302 M, mean age 64±12 years) with cardiac implantable devices (127 with CRTD, 233 with ICD). During observation, which lasted the mean of 768±491 days, 258 patients had ventricular arrhythmias and 118 patients had adequate device interventions. 10 patients died because of the progression of heart failure. Ventricular arrhythmia was more frequent in patients with CRTD, who died, with low cholesterol level, high NYHA class, low LVEF, diabetes and kidney failure. Device interventions occurred in the above described groups and additionally in patients with AF. After step exclusion of characteristics with highest p value in Wald test, it was confirmed that the factors influencing ventricular arrhythmia and death were low LVEF (HR=0,944, p<0,002 and HR=0,813, p<0,013) and diabetes (HR=7,043, p<0,009 and HR=29,931, p<0,002).

CONCLUSIONS

Ventricular arrhythmia is more often in patients with CRTD, who died, with low cholesterol level, high NYHA class, low LVEF, diabetes and kidney failure. Adequate interventions are more often in patients who died, with low cholesterol level, high NYHA class, low LVEF, diabetes, kidney failure and AF. Patients who died, compared to those who survived, had significantly more often lipid level anomalies, high NYHA class, low LVEF, advanced age, diabetes, kidney failure, atrial fibrillation, arterial hypertension, device interventions and pharmacotherapy changes. Diabetes and low LVEF are predictors of ventricular arrhythmias and death.

Для цитирования: Lelakowski Jacek, Pudło Joanna, Lelakowska-Pieła Maria, Rydlewska Anna, Piekarz Justyna, Domaracki Donat. [Arrhythmia, device interventions and mortality analysis in patients with implanted cardioverter-defibrillator with/without resynchronisation therapy in dilative cardiomyopathy in primary prevention of sudden cardiac death].. Polski merkuriusz lekarski : organ Polskiego Towarzystwa Lekarskiego. 2016.